ZSL1-1B,Type B Residual Current Circuit Breaker (RCCB), magnetic Industrial-Grade Leakage Protection (16-100A) - S-Mark & Fabricant de RCBO KEMA | ZHISHUN ELECTRICTRIC

RCCB/

ZSL1-1B,Type B Residual Current Circuit Breaker (RCCB), magnetic Industrial-Grade Leakage Protection (16-100A)

Premium Safety Features:
✔ High-Capacity Protection - 100A rating for demanding commercial/industrial use
✔ Type AC/A Detection - Reliable AC & pulsating DC leakage protection
✔ Multi-Voltage Support - 230/400V~240/415V systems compatibility
Technical Specifications:

  • Standards: IEC 61008-1 certified
  • Poles: 2P(1P+N), 4P(3P+N) - N left
  • Sensitivity: 30/100/300mA selectable
  • Temperature Range: -25°C to +40°C
  • Installation: Top/bottom wiring
  • Certifications: CE, CB, TUV, UKCA

Ideal For:

  • Manufacturing plants
  • Commercial buildings
  • High-power electrical distribution

  • Product Details
  • Why Customers Choose the ODL26-100B Type B RCCB
  • Emballage & Livraison
  • FAQ
ZSL1-1B Type B RCCB is a cutting-edge residual current device designed to meet the evolving safety demands of modern electrical installations. With its 100A capacity and ability to detect a wide range of leakage currents, this robust RCCB is perfectly suited for high-power applications in industrial environments, renewable energy systems, and EV charging infrastructure. The ZSL1-1B ensures enhanced safety and reliability, protecting both personnel and equipment from the risks associated with electrical leakage.

Key Features:

Advanced Safety Features of ZSL1-1B Type B RCCB:

✔ Complete Leakage Protection - Safeguards against all current types including AC, pulsating DC and smooth DC for ultimate electrical safety

✔ Heavy-Duty Performance - 100A capacity handles the most demanding industrial power requirements

✔ Extended Frequency Coverage - Protects systems operating at frequencies up to 1000Hz (perfect for modern VFDs and inverters)

✔ Ultra-Sensitive Detection - Instant response to minimal leakage currents (as low as 10mA) for enhanced personnel protection

✔ Industrial-Grade Construction - Engineered with premium components for reliable operation in tough environments

✔ User-Friendly Design - Simple DIN rail mounting with intuitive visual indicators for quick status checks

✔ Worldwide Compliance - Fully certified to international Type B RCCB standards for guaranteed safety
Applications:
• Key Applications:
• EV charging stations & infrastructure
• Solar & renewable energy systems
• Industrial automation & machinery
• Data centers & IT infrastructure
• Welding & metalworking equipment
• Medical & diagnostic facilities
The ZSL1-1B Type B Residual Current Device (RCD)  from ZHISHUN Electric is the ultimate solution for high-power applications requiring advanced electrical safety. By selecting the ZSL1-1B, you can ensure the highest level of protection for your equipment and personnel, guaranteeing a safer and more reliable electrical system.
Technical parameters
CategorySpecificationKey Feature
StandardsIEC 61008-1, IEC 62423Internationally certified
Protection TypeGround fault (Electromagnetic trip)Type B leakage detection
Current DetectionAC + Pulsating/Smooth DC (≤1kHz)Full-spectrum protection
Pole Configurations2P(1P+N), 4P(3P+N) – N leftFlexible installation options
Current Ratings2P: 16-63A (80-100A in 3 modules)
4P: 16-100A
High-power applications
Voltage Ratings2P: 110/230/240V
4P: 240/400/415V
Multi-voltage compatibility
Insulation500VEnhanced safety barrier
Sensitivity30/100/300mAAdjustable protection levels
Breaking Capacity10kA short-circuit
500A (≤50A)
10In (>50A)
Industrial-grade interruption
Response Time≤0.1sUltra-fast fault response
Durabilité2,000 electrical cycles
4,000 mechanical cycles
Long service life
IndicatorsPower: Green(OFF)/Red(ON)
Fault: White(Normal)/Red(Leakage)
Instant status visibility
Environmental-25°C to +40°C, 95% humidityHarsh environment operation
TerminalsCable/Pin-type/Fork-type busbar
35mm² max cable
Versatile connection options
Installation35mm DIN rail
Bidirectionnel
Quick deployment

Dimensions

1. Unmatched Leakage Protection

✅ Type B Detection – Covers AC, courant continu pulsé, and smooth DC leakage currents, essential for:

  • EV chargers (DC leakage risks)
  • Solar inverters (high-frequency residual currents)
  • Industrial VFDs (complex waveforms)

✅ Ultra-Sensitive Response – Detects leakage as low as 10mA, preventing:

  • Electric shocks (30mA sensitivity)
  • Equipment damage (100/300mA settings)

2. Built for High-Power Demands

🔹 100A Current Rating – Handles heavy loads in:

  • Factories (motors, welding equipment)
  • Data centers (server racks, UPS systems)
  • Renewable energy plants (solar/wind farms)

🔹 10kA Short-Circuit Capacity – Ensures safety during major faults.

3. Industrial-Grade Reliability

⚡ Large gamme de fréquences (0-1000Hz) – Protects modern electronics with inverters/VFDs. ⚡ -25°C to +40°C Operation – Works in extreme temperatures. ⚡ IP20 Protection – Resists dust and accidental contact.

4. Easy to Deploy & Maintain

🔧 DIN Rail Mounting – Quick installation in panels. 🔧 Bidirectional Wiring – Flexible connection options. 🔧 Visual Indicators – Clear Green/Red (ON/OFF) and Leakage Fault (Red) alerts.

5. Globally Trusted

🌍 Certified to IEC 61008-1, IEC 62423 – Compliant in UE, Royaume-Uni, and worldwide. 🌍 CE, CB, TUV, UKCA Marks – Meets strict safety regulations.


Key Customer Benefits

✔ Future-Proof Safety – Handles modern electrical systems (EVs, renewables, Industry 4.0). ✔ Reduces Downtime – Robust design minimizes failures in harsh conditions. ✔ Simplifies Compliance – Pre-approved for international markets. ✔ Saves Costs – Replaces multiple devices with one advanced RCCB. Ideal For:

  • Engineers needing reliable Type B protection
  • EV Charger Installers requiring DC leakage detection
  • Industrial Facilities with sensitive machinery
  • Solar Contractors working with inverters

Choix d'expédition

Q1: Vous demandez-vous si vous acceptez de petites commandes? A1: Ne vous inquiétez pas. N'hésitez pas à nous contacter pour obtenir plus de commandes et offrir plus de commodité à nos clients ,nous acceptons les petites commandes. Q2: Pouvez-vous envoyer des produits dans mon pays? A2: Bien sûr, nous le pouvons. Si vous n'avez pas votre propre transitaire, nous pouvons vous aider. Q3: Pouvez-vous faire de l'OEM pour moi? A3: Nous acceptons toutes les commandes OEM,contactez-nous simplement et donnez-moi votre design. Nous vous offrirons un prix raisonnable et réaliserons des échantillons pour vous dès que possible. Q4: Quels sont vos conditions de paiement ? A4: Par T/T,LC À VUE,30% dépôt à l'avance, solde 70% contre copie du connaissement. Q5: Comment puis-je passer la commande? A5: D'abord signez le PI,payez le dépôt,puis nous organiserons la production. Après que les marchandises auront été produites, nous vous enverrons la copie du connaissement puis vous paierez. Enfin, vous recevrez les marchandises. Q7: Quand puis-je obtenir le devis ? A7: Nous vous donnons généralement un devis dans 24 heures après réception de votre demande. Si vous avez très urgemment besoin du devis, veuillez nous appeler ou nous le dire dans votre mail, afin que nous puissions considérer votre demande comme prioritaire.