Courriel: orcbo@orcbo.com


ZSR3-1,Mini RCBO modulaire simple,10kA, Type A, DDR avec protection contre les surintensités,1P+N - S-Mark & Fabricant de RCBO KEMA | ZHISHUN ELECTRICTRIC

RCBO/

ZSR3-1,Mini RCBO modulaire simple,10kA, Type A, DDR avec protection contre les surintensités,1P+N

ZSR3-1 RCBO - Protection compacte 1P+N (6-50A, 10kA, Type A/AC)

Caractéristiques clés:

  • Sécurité tout-en-un - Combine DDR (30/100/300mA) + MCB in single module

  • Type A detection - Capture les défauts AC + DC pulsé (idéal pour les VE/solaire)

  • Pouvoir de coupure élevé 10 kA - Reliable protection for demanding installations

  • B/C tripping curves - B (3-5x) pour les habitations, C (5-10x) for industrial loads

  • Full isolation - Interrompt à la fois la phase et le neutre & Neutral for complete circuit disconnect

Technical Highlights:

  • Current range: 6A-50A (6,10,16,20,25,32,40,50A)

  • Electronic trip mechanism

  • Neutral switching for fast installation

  • 1P+N space-saving design

  • IEC/EN 61009-1 certified

Why Choose ZSR3-1?
✔ Space-efficient - Replaces two devices in one
✔ Future-proof - Type A handles modern electronics
✔ Industrial-grade - 10kA capacity for tough environments
✔ Easy install - Neutral switching saves time

Perfect For:

  • Residential consumer units

  • Commercial distribution boards

  • EV charging stations

  • Solar PV systems

  • High-rise building power

  • Détails du produit
  • Why Choose the ODL-50 RCBO
  • FAQ
  • Emballage & Livraison
Introduction:

ZSR3-1 RCBO – Smart 1P+N Circuit Protection (6-50A, 10kA, Type A/AC)

Complete Electrical Safety in One Device

The ZSR3-1 RCBO combines courant résiduel (RCD) + overcurrent (MCB) protection in a single compact module, ensuring safety against:
✔ Earth faults (30mA/100mA/300mA sensitivity)
✔ Overloads & short circuits (B/C tripping curves)
✔ DC leakage risks (Type A detects pulsating DC – essential for EV/solar systems)

Key Advantages

🔹 Déconnexion totale L+N – Fonctionne même si le câblage est inversé
🔹 Electronic Filtering – Prevents false tripping from power surges
🔹 10kA Breaking Capacity – Handles high fault currents
🔹 Space-Saving 1P+N Design – More room in enclosures for easier wiring
🔹 Neutral Switching – Faster installation & testing

Technical Highlights
  • Type A/AC Options – Type A for DC-sensitive circuits (EV/solar), Type AC for standard AC

  • B & C Curves – B (3-5x In) pour les habitations, C (5-10x In) for commercial/industrial

  • Rated Currents – 6A to 50A (6,10,16,20,25,32,40,50A)

  • Certified Safety – Complies with IEC/EN 61009-1, AS/NZS 61009.1

Why Installers & Engineers Choose ODL-50?

✅ No Nuisance Tripping – Stable performance in mission-critical circuits
✅ Safer Testing – No need to disconnect L/N during checks
✅ Fault Isolation – Only the faulty circuit shuts off, keeping others live
✅ Future-Ready – Protects modern electronics & renewable energy systems

Best Applications

🏠 Homes – Prévient les chocs & fires
🏢 Commercial Buildings – Handles fluorescent lighting & motors
🔌 Chargeurs EV – Type A ensures DC leakage protection
☀️ Systèmes solaires – Reliable performance with inverters

Product Description:

ZSR3-1 RCBO – Protection compacte 1P+N (2-40A, 6kA, Type A/AC)

Complete Safety Solution:
✔ Combines RCD (30/100mA) + MCB in single module
✔ Type A (AC+DC) or Type AC protection
✔ 6kA breaking capacity with B/C tripping curves

Caractéristiques clés:

  • 2A to 40A current range (2,6,10,16,20,25,32,40A)

  • Full L+N disconnection for complete isolation

  • Neutral switching for faster installation/testing

  • Clear ON/OFF indicator (Green=OFF, Red=ON)

  • 35mm DIN rail mounting (EN 60715)

Technical Specifications:

  • Voltage: 110V/230V AC (1P+N)

  • 6kV impulse withstand

  • 20,000 mechanical operations

  • Protection IP20

  • Operating temp: -5°C to +40°C

Installation:

  • Top/bottom wiring options

  • Accepts 25mm² cable (18-3 AWG)

  • 2.5N·m tightening torque

Certified: IEC/EN/AS/NZS 61009-1

Best for: Homes, EV chargers, systèmes solaires

CategoryParameterSpecification
StandardComplianceIEC/EN 61009-1
Electrical FeaturesRated Current (In)6,10,16,20,25,32,40,50A
TypeElectronic
Leakage Detection TypeType A or AC
Poles1P+N (Switched Live and Neutral)
Rated Voltage (Ue)230/240V
Sensitivity (IΔn)30mA,100mA,300mA
Insulation Voltage (Ui)500V
Frequency50/60Hz
Breaking Capacity10kA
Residual Making/Breaking Capacity (IΔm)3000A
Impulse Withstand Voltage (1.2/50μs)4000V
Trip Time (IΔn)≤0.1s
Pollution Degree2
Tripping CharacteristicB, C Curve
Mechanical FeaturesElectrical Life2,000 operations
Mechanical Life2,000 operations
Contact IndicatorYes
Protection DegreeIP20
Reference Temperature30°C
Operating Temperature-5°C to +40°C
Storage Temperature-25°C to +70°C
InstallationTerminal TypeCable/Pin-type busbar
Top Terminal (Cable)10mm²
Bottom Terminal (Cable)16mm² / 18-8 AWG
Bottom Terminal (Busbar)10mm² / 18-8 AWG
Couple de serrage2.5N·m / 22 In-lbs
Montage35mm Rail DIN (EN 60715)
ConnexionFrom bottom

ODL-50 Dimensions

Single Module Mini RCBO with Switched Live and Neutral 6kA  JCR1-40_1 (1)

Why use Miniature RCBOs?
RCBO (Residual Current Circuit Breakers with Overcurrent Protection) devices are a combination of an RCD (Residual Current Device) and MCB (Miniature Circuit Breaker) in one.
An RCD detects Earth Leakage, i.e. current flowing where it shouldn’t, switching the circuit off where there is an Earth fault current. The RCD element of the RCBO is there to protect people.
In housing installations it’s not unusual to find that one or more RCDs are used alongside MCBs in the consumer unit, all grouped together protecting multiple circuits. What commonly happens when there is an earth fault on one circuit is that a whole group of circuits, including healthy circuits, are switched off.
In these instances, using RCDs and MCBs in groups goes against specific aspects of the IET’s 17th Edition Wiring Regulations. Specifically, Chapter 31-Division of Installation, regulation 314.1, which requires every installation to be divided into circuits as necessary –
1)To avoid danger in the event of a fault
2)To facilitate safe inspection, testing and maintenance
3)To take account of hazards that might arise from the failure of a single circuit e.g. lighting circuit
4)To reduce the possibility of unwanted tripping of RCDs (not due to fault)

Why Choose the ODL-50 RCBO?

1. Comprehensive Protection in a Single Device

✅ Combine DDR (Fuite de terre) + MCB (Surcharge/Court-circuit) Protection

  • Gain de place 1Conception P+N reduces panel clutter

  • Type A (AC+DC Detection) for EV chargers, solar inverters, and electronics with DC components

  • Type AC for standard AC circuits

✅ High 10kA Breaking Capacity

  • Handles industrial-level fault currents for reliable protection

✅ B/C Tripping Curves

  • B Curve (3-5x In) – Ideal for homes (lighting, sockets)

  • C Curve (5-10x In) – Best for commercial/industrial loads (motors, fluorescent lighting)


2. Superior Reliability & Safety Compliance

🔹 Electronic Trip Mechanism – Resists nuisance tripping from power surges
🔹 Déconnexion totale L+N – Fonctionne même si le câblage est inversé
🔹 Ultra-Fast Tripping (≤0.1s at 30mA) – Prevents electric shocks
🔹 IP20 Rated – Safe for standard enclosures
🔹 Wide Temp Range (-25°C to +70°C) – Suitable for harsh environments


3. Installation facile, Faster Commissioning

🔧 Bottom Wiring – Simplifies connections
🔧 35mm DIN Rail Mounting – Fits standard panels
🔧 Neutral Switching – Enables testing without disconnecting wires
🔧 10mm²/16mm² Terminals – Supports thick cables


4. Ideal Applications

🏠 Homes – Shock protection for families
🏢 Commercial/Industrial – Moteurs, HVAC, LED lighting
🔌 Chargeurs EV – Type A détecte les fuites DC (critical for EVs)
☀️ Systèmes solaires – Handles DC fault currents


Key Advantages

✔ All-in-One Design – Saves space & cost
✔ Type A/AC Options – Future-proof for modern tech
✔ 10kA Industrial Protection – Highest safety standard
✔ Quick Install – Bottom entry + DIN rail
✔ Global Certifications – IEC/EN 61009-1 compliant

SEO Keywords:
Type A RCBO, 10kA circuit breaker, 1P+N RCD+MCB, EV charger protection, solar-ready RCBO


Perfect For: Electricians, OEMs, solar installers, EV charging providers

Q1: Vous demandez-vous si vous acceptez de petites commandes?

A1: Ne vous inquiétez pas. N'hésitez pas à nous contacter pour obtenir plus de commandes et offrir plus de commodité à nos clients ,nous acceptons les petites commandes.

Q2: Pouvez-vous envoyer des produits dans mon pays?

A2: Bien sûr, nous le pouvons. Si vous n'avez pas votre propre transitaire, nous pouvons vous aider.

Q3: Pouvez-vous faire de l'OEM pour moi?

A3: Nous acceptons toutes les commandes OEM,contactez-nous simplement et donnez-moi votre design. Nous vous offrirons un prix raisonnable et réaliserons des échantillons pour vous dès que possible.

Q4: Quels sont vos conditions de paiement ?

A4: Par T/T,LC À VUE,30% dépôt à l'avance, solde 70% contre copie du connaissement.

Q5: Comment puis-je passer la commande?

A5: D'abord signez le PI,payez le dépôt,puis nous organiserons la production. Après que les marchandises auront été produites, nous vous enverrons la copie du connaissement puis vous paierez. Enfin, vous recevrez les marchandises.

Q7: Quand puis-je obtenir le devis ?

A7: Nous vous donnons généralement un devis dans 24 heures après réception de votre demande. Si vous avez très urgemment besoin du devis, veuillez nous appeler ou nous le dire dans votre mail, afin que nous puissions considérer votre demande comme prioritaire.

Tous nos câbles à fibre optique sont livrés avec un tambour en bois pour l'exportation. Dimensions du tambour en bois pour câble FTTH intérieur : 50x50x32 cm, Longueur de livraison : 3 km/tambour, Dimensions du tambour en bois pour câble à fibre optique extérieur : 110 cm*110 cm*70 cm, 0.85CBM, peut charger environ 33 tambours pour un conteneur 20GP. Acceptons également les tambours de câble personnalisés des clients. Bienvenue à nous contacter! GYTS Direct Burial Single Armored Double Sheath Fiber Optic Cable GYTS Fiber Optic Cable Picture Choix d'expédition

Précédent:

Suivant:

Laisser un commentaire

Laisser un message