ZSR3-1 RCBO - Compact 1P+N Protection (6-50A, 10kA, Type A/AC)

Hauptmerkmale:

  • All-in-one safety - Kombiniert FI-Schutzschalter (30/100/300mA) + MCB in single module

  • Type A detection - Erfasst AC + pulsierenden DC-Fehlerströmen (ideal for EV/solar)

  • High 10kA breaking - Reliable protection for demanding installations

  • B/C tripping curves - B (3-5x) für Wohnhäuser, C (5-10x) for industrial loads

  • Full isolation - Switches both Live & Neutral for complete circuit disconnect

Technische Highlights:

  • Current range: 6A-50A (6,10,16,20,25,32,40,50A)

  • Electronic trip mechanism

  • Neutral switching for fast installation

  • 1P+N space-saving design

  • IEC/EN 61009-1 certified

Why Choose ZSR3-1?
✔ Space-efficient - Replaces two devices in one
✔ Future-proof - Type A handles modern electronics
✔ Industrial-grade - 10kA capacity for tough environments
✔ Easy install - Neutral switching saves time

Perfect For:

  • Residential consumer units

  • Commercial distribution boards

  • EV-Ladestationen

  • Solar PV systems

  • High-rise building power

  • Produktdetails
  • Why Choose the ODL-50 RCBO
  • FAQs
  • Verpackung & Lieferung
Einführung:

ZSR3-1 RCBO – Smart 1P+N Circuit Protection (6-50A, 10kA, Type A/AC)

Complete Electrical Safety in One Device

The ZSR3-1 RCBO kombiniert Fehlerstrom (RCD) + overcurrent (MCB) Schutz in a single compact module, ensuring safety against:
✔ Earth faults (30mA/100mA/300mA sensitivity)
✔ Overloads & short circuits (B/C tripping curves)
✔ DC leakage risks (Type A detects pulsating DC – essential for EV/solar systems)

Hauptvorteile

🔹 Full L+N Disconnection – Works even if wiring is reversed
🔹 Electronic Filtering – Prevents false tripping from power surges
🔹 10kA-Schaltvermögen – Handles high fault currents
🔹 Space-Saving 1P+N Design – More room in enclosures for easier wiring
🔹 Neutral Switching – Faster installation & testing

Technische Highlights
  • Type A/AC Options – Type A for DC-sensitive circuits (EV/solar), Type AC for standard AC

  • B & C Curves – B (3-5x In) für Wohnhäuser, C (5-10x In) for commercial/industrial

  • Rated Currents – 6A to 50A (6,10,16,20,25,32,40,50A)

  • Certified Safety – Complies with IEC/EN 61009-1, AS/NZS 61009.1

Why Installers & Engineers Choose ODL-50?

✅ No Nuisance Tripping – Stable performance in mission-critical circuits
✅ Safer Testing – No need to disconnect L/N during checks
✅ Fault Isolation – Only the faulty circuit shuts off, keeping others live
✅ Future-Ready – Protects modern electronics & renewable energy systems

Best Applications

🏠 Homes – Prevents shocks & fires
🏢 Gewerbliche Gebäude – Handles fluorescent lighting & motors
🔌 EV Chargers – Type A ensures DC leakage protection
☀️ Solar Systems – Reliable performance with inverters

Produktbeschreibung:

ZSR3-1 RCBO – Compact 1P+N Protection (2-40A, 6kA, Type A/AC)

Complete Safety Solution:
✔ Combines RCD (30/100mA) + MCB in single module
✔ Type A (AC+DC) or Type AC protection
✔ 6kA breaking capacity with B/C tripping curves

Hauptmerkmale:

  • 2A to 40A current range (2,6,10,16,20,25,32,40A)

  • Full L+N disconnection for complete isolation

  • Neutral switching for faster installation/testing

  • Clear ON/OFF indicator (Green=OFF, Red=ON)

  • 35mm Hutschienenmontage (EN 60715)

Technische Daten:

  • Voltage: 110V/230V AC (1P+N)

  • 6kV impulse withstand

  • 20,000 mechanical operations

  • IP20-Schutz

  • Operating temp: -5°C bis +40°C

Installation:

  • Top-/Bottom-Verdrahtungsoptionen

  • Accepts 25mm² cable (18-3 AWG)

  • 2.5N·m tightening torque

Certified: IEC/EN/AS/NZS 61009-1

Best for: Homes, EV-Ladegeräte, Solaranlagen

KategorieParameterSpezifikation
StandardComplianceIEC/EN 61009-1
Electrical FeaturesRated Current (In)6,10,16,20,25,32,40,50A
TypeElectronic
Leakage Detection TypeType A or AC
Poles1P+N (Switched Live and Neutral)
Nennspannung (Ue)230/240V
Sensitivity (IΔn)30mA,100mA,300mA
Isolationsspannung (Ui)500V
Frequency50/60Hz
Breaking Capacity10kA
Residual Making/Breaking Capacity (IΔm)3000A
Impulse Withstand Voltage (1.2/50μs)4000V
Trip Time (IΔn)≤0.1s
Pollution Degree2
Tripping CharacteristicB, C-Kurve
Mechanical FeaturesElectrical Life2,000 Betriebsvorgänge
Mechanische Lebensdauer2,000 Betriebsvorgänge
Contact IndicatorJa
SchutzartIP20
Reference Temperature30°C
Betriebstemperatur-5°C bis +40°C
Lagertemperatur-25°C to +70°C
InstallationTerminal TypeCable/Pin-type busbar
Top Terminal (Cable)10mm²
Bottom Terminal (Cable)16mm² / 18-8 AWG
Bottom Terminal (Busbar)10mm² / 18-8 AWG
Tightening Torque2.5N·m / 22 In-lbs
Montage35mm DIN Rail (EN 60715)
AnschlussFrom bottom

ODL-50 Dimensions

Single Module Mini RCBO with Switched Live and Neutral 6kA  JCR1-40_1 (1)

Why use Miniature RCBOs?
RCBO (Fehlerstrom-Schutzschalter mit Überstromschutz) devices are a combination of an RCD (Residual Current Device) and MCB (Miniatur-Leistungsschalter) in one.
An RCD detects Earth Leakage, i.e. current flowing where it shouldn’t, switching the circuit off where there is an Earth fault current. The RCD element of the RCBO is there to protect people.
In housing installations it’s not unusual to find that one or more RCDs are used alongside MCBs in the consumer unit, all grouped together protecting multiple circuits. What commonly happens when there is an earth fault on one circuit is that a whole group of circuits, including healthy circuits, are switched off.
In these instances, using RCDs and MCBs in groups goes against specific aspects of the IET’s 17th Edition Wiring Regulations. Specifically, Chapter 31-Division of Installation, regulation 314.1, which requires every installation to be divided into circuits as necessary –
1)To avoid danger in the event of a fault
2)To facilitate safe inspection, testing and maintenance
3)To take account of hazards that might arise from the failure of a single circuit e.g. lighting circuit
4)To reduce the possibility of unwanted tripping of RCDs (not due to fault)

Why Choose the ODL-50 RCBO?

1. Comprehensive Protection in a Single Device

✅ Kombiniert FI-Schutzschalter (Earth Leakage) + MCB (Overload/Short-Circuit) Protection

  • Space-saving 1P+N design reduces panel clutter

  • Type A (AC+DC Detection) for EV chargers, solar inverters, and electronics with DC components

  • Type AC for standard AC circuits

✅ High 10kA Breaking Capacity

  • Handles industrial-level fault currents for reliable protection

✅ B/C Tripping Curves

  • B-Kurve (3-5x In) – Ideal for homes (lighting, sockets)

  • C-Kurve (5-10x In) – Best for commercial/industrial loads (motors, fluorescent lighting)


2. Superior Reliability & Safety Compliance

🔹 Electronic Trip Mechanism – Resists nuisance tripping from power surges
🔹 Full L+N Disconnection – Works even if wiring is reversed
🔹 Ultra-Fast Tripping (≤0.1s at 30mA) – Prevents electric shocks
🔹 IP20 Rated – Safe for standard enclosures
🔹 Wide Temp Range (-25°C to +70°C) – Suitable for harsh environments


3. Easy Installation, Faster Commissioning

🔧 Bottom Wiring – Simplifies connections
🔧 35mm DIN Rail Mounting – Fits standard panels
🔧 Neutral Switching – Enables testing without disconnecting wires
🔧 10mm²/16mm² Terminals – Supports thick cables


4. Ideale Anwendungen

🏠 Homes – Shock protection for families
🏢 Commercial/Industrial – Motoren, HVAC, LED lighting
🔌 EV Chargers – Type A detects DC leakage (critical for EVs)
☀️ Solar Systems – Handles DC fault currents


Hauptvorteile

✔ All-in-One Design – Saves space & cost
✔ Type A/AC Options – Future-proof for modern tech
✔ 10kA Industrial Protection – Highest safety standard
✔ Quick Install – Bottom entry + DIN rail
✔ Global Certifications – IEC/EN 61009-1 konform

SEO Keywords:
Type A RCBO, 10kA circuit breaker, 1P+N RCD+MCB, EV charger protection, solar-ready RCBO


Perfect For: Electricians, OEMs, solar installers, EV charging providers

Q1: Ob Sie kleine Bestellungen akzeptieren?

A1: Keine Sorge. Zögern Sie nicht, uns zu kontaktieren, um mehr Bestellungen zu erhalten und unseren Kunden mehr Komfort zu bieten ,Wir akzeptieren kleine Bestellungen.

Q2: Können Sie Produkte in mein Land liefern?

A2: Natürlich, Wir können. Wenn Sie keinen eigenen Spediteur haben, können wir Ihnen helfen.

Q3: Können Sie OEM für mich durchführen?

A3: Wir akzeptieren alle OEM-Bestellungen,just contact us and give me your design.we will offer you a reasonable price and make samples for you ASAP.

Q4: What’s your payment terms ?

A4: By T/T,LC AT SIGHT,30% deposit in advance, balance 70% against the copy of B/L.

Q5: How can I place the order?

A5: First sign the PI,Anzahlung leisten,dann werden wir die Produktion arrangieren. Nachdem die Waren produziert sind, senden wir Ihnen die Kopie des Frachtbriefs, dann zahlen Sie. Schließlich erhalten Sie die Waren.

F7: Wann kann ich das Angebot erhalten? ?

A7: Wir machen Ihnen normalerweise innerhalb von 24 Stunden nach Erhalt Ihrer Anfrage ein Angebot. Wenn Sie sehr dringend ein Angebot benötigen, rufen Sie uns bitte an oder teilen Sie es uns in Ihrer E-Mail mit, damit wir Ihre Anfrage vorrangig behandeln können.

All of our fiber optic cable package are with export wooden drum. Indoor FTTH cable’s wooden dimension is 50x50x32cm, delivery length 3km/drum, Outdoor fiber optic cable’s wooden dimension is 110cm*110cm*70cm, 0.85CBM, can be load about 33 drums for a 20GP.Also accept custom cable drum from customers. welcome to contact us! GYTS Direct Burial Single Armored Double Sheath Fiber Optic Cable GYTS Fiber Optic Cable Picture Versandoption

Zurück:

Weiter:

Hinterlasse eine Antwort

Hinterlasse eine Nachricht