Электронная почта: orcbo@orcbo.com


ZSR7-1, RCBO 10kA, Magnetic TypeA, Residual Current Operated Circuit Breaker, 2Pole, 1Фаза+Ноль - S-Mark & Производитель RCBO KEMA | ZHISHUN ELECTRICTRIC

RCBO/

ZSR7-1, RCBO 10kA, Magnetic TypeA, Residual Current Operated Circuit Breaker, 2Pole, 1Фаза+Ноль

ZSR7-1 RCBO - Smart Electronic Protection for Modern Electrical Installations

Comprehensive Circuit Protection Solution
The OSR7-40 electronic RCBO delivers advanced residual current and overcurrent protection in a single compact device, designed for superior performance in:

  • Residential complexes
  • Commercial establishments
  • Industrial facilities
  • High-rise buildings

Key Technical Features:

✔ Dual Protection System

  • 30mA/100mA/300mA residual current detection (Устройство защитного отключения (УЗО))
  • Защита от перегрузки и короткого замыкания (MCB)
  • Electronic tripping mechanism for precise operation

✔ Flexible Configuration Options

  • Standard 6kA breaking capacity (upgradeable to 10kA)
  • Current ratings: 6A to 40A (multiple options)
  • B and C tripping characteristics available
  • Type A (AC+DC) or Type AC versions

✔ Enhanced Safety Design

  • Complete double-pole circuit isolation
  • Neutral pole switching for efficient installation
  • Complies with IEC 61009-1 & EN61009-1 standards

Installation Advantages:

  • Space-saving single-module design
  • Simplified wiring with neutral switching
  • Compatible with standard distribution boards
  • Easy integration into existing systems

ZSR7-1 RCBO Key Specifications

  • Protection Type: Electronic
  • Breaking Capacity: 6кА (10kA upgrade available)
  • Rated Current: 6A-40A (6,10,16,20,25,32,40A)
  • Tripping Curves: B, C
  • Sensitivity: 30mA/100mA/300mA
  • Detection Type: Type A/AC
  • Standards: IEC 61009-1, EN61009-1
  • Operating Voltage: 230/240V AC
  • Protection Class: IP20

  • Product Details
  • Why Choose OSR7-40 RCBO
  • Packing & Delivery
  • FAQs
ZSR7-1 RCBO | Electronic Type A/AC Circuit Breaker (6-40A) | 6kA/10kA Protection
Advanced Dual Protection for Electrical Safety
The ZSR7-1 RCBO combines residual current (Устройство защитного отключения (УЗО)) and overcurrent (MCB) protection in one compact device, ensuring complete safety against:
• Earth leakage faults (30mA/100mA/300mA sensitivity)
• Circuit overloads & short circuits (B/C tripping curves)
• DC current risks (Type A version for EV/solar applications)
Key Benefits for Installers & Homeowners
Full Neutral+Phase Disconnection – Works even if wiring is reversed
Electronic Filtering – Prevents false tripping from voltage spikes
Type A & AC Options – Type A detects pulsating DC (essential for EV chargers)
Wide Current Range 6A to 40A (residential/commercial use)
6kA Breaking Capacity – Upgradeable to 10кА for high-demand systems
Test Button Included – Easy safety verification

Technical Specifications
FeatureSpecification
TypeElectronic RCBO
ProtectionEarth leakage + Overload/Short-circuit
Rated Current6A, 10A, 16A, 20A, 25A, 32A, 40A
Voltage110V (low voltage) / 230V-240V
Sensitivity30mA (personal), 100mA/300mA (fire protection)
Tripping CurveB Curve (3-5x In) / C Curve (5-10x In)
Breaking Capacity6кА (10kA upgrade available)
DisconnectionDouble-pole (Фаза+Ноль)
StandardsIEC 61009-1, EN 61009-1

Why Choose ZSR7-1?
🏠 For Homes
Предотвращает поражение электрическим током (30mA sensitivity)
Stops electrical fires from faulty wiring
 
🔌 For EV Chargers & Solar
Type A version detects DC leakage currents
Complies with EV installation regulations
🏢 For Commercial Use
C Curve handles motor/compressor startups
100mA/300mA options reduce fire risks
Product Description
ZSR7-1 RCBO | Electromagnetic Type A/AC Circuit Breaker (6-40A) | 6kA/10kA Protection

Complete Electrical Protection for Modern InstallationsThe ZSR7-1 electromagnetic RCBO delivers dual safety by combining earth leakage protection (Устройство защитного отключения (УЗО)) and overcurrent protection (MCB) in one compact device. Ideal for residential, коммерческих, and industrial applications where reliable circuit protection is critical.

Key Safety Features
✔ Double-Pole DisconnectionSimultaneously cuts both Live & Neutral
✔ Type A DetectionCatches pulsating DC faults (essential for EV chargers)
✔ 6kA Breaking CapacityUpgradeable to 10kA for demanding installations
✔ B/C Tripping CurvesB Curve (3-5x In) for homes | C Curve (5-10x In) for industry
✔ 30mA/100mA/300mA SensitivityPersonal shock vs. fire protection
Why Professionals Choose ZSR7-1?
✅ Neutral SwitchingFaster installation/testing
✅ Insulated OpeningsSafer busbar connections
✅ Universal CompatibilityWorks with all standard screwdrivers
✅ Visual IndicatorsClear ON/OFF status (Red/Green)
✅ Flexible WiringTop or bottom cable entry
Ideal Applications

• EV Charging Stations (Type A version)
• Solar PV Systems
• Home Consumer Units
• Commercial Distribution Boards
• Industrial Control Panels
Upgrade your electrical protection today with ZSR7-1 - the smarter choice for safety-conscious installations!

Technical Specifications
CategoryParameterSpecification
СертификацияStandards ComplianceIEC 61009-1, EN 61009-1
ElectricalRated Current (In)6,10,16,20,25,32,40,50,63,80A
Device TypeElectronic
Detection TypeType A (AC+DC) / Type AC
Poles2 Pole (1Фаза+Ноль)
Rated Voltage (Ue)230/240V
Sensitivity (IΔn)30mA,100mA,300mA
Insulation Voltage (Ui)500V
Frequency50/60Hz
Breaking Capacity6кА
Impulse Withstand Voltage6kV (1.2/50μs)
Pollution Degree2
Tripping CharacteristicB, C Curve
MechanicalElectrical Life2,000 operations
Mechanical Life10,000 operations
Contact IndicatorYes (Visual ON/OFF)
Protection DegreeIP20
Reference Temperature30°C
Operating Temperature-5°C to +40°C
Storage Temperature-25°C to +70°C
InstallationTerminal TypeCable/U-type/Pin-type busbar
Cable Size (Top/Bottom)25mm² / 18-3 AWG
Busbar Size (Top/Bottom)10mm² / 18-8 AWG
Tightening Torque2.5N·m (22 In-lbs)
Mounting35mm DIN Rail (EN 60715)
Connection DirectionTop or Bottom

Dimensions

Dimensions

JCB2LE-80M Dimension
What is an RCBO and How Does it Work?

RCBO stands for 'Residual Current Breaker with Over-Current'. As the name suggests it protects against two types of fault and in essence combines the functionality of an MCB and RCD.
Let us first remind ourselves of those two faults:

1.Residual Current, or Earth Leakage - Occurs when there is an accidental break in a circuit through poor electrical wiring or DIY accidents such as drilling through a cable when mounting a picture hook or cutting through a cable with the lawn mower. In this instance the electricity must go somewhere and choosing the easiest route travels through the lawnmower or drill to the human causing electric shock.

2.Over-Current takes two forms:
2.1 Overload - Occurs when too many devices are in use on the circuit, drawing an amount of power which exceeds the capacity of the cable.
2.2 Short Circuit - Occurs when there is a direct connection between the live and neutral conductors. Without the resistance provided by the normal circuit integrity, electrical current rushes around the circuit in a loop and multiplies the amperage by many thousand times in just milliseconds and is considerably more dangerous than Overload.
Whereas an RCD is designed solely to protect against earth leakage and an MCB protects only against over-current, an RCBO protects against both types of fault.

  • Reliable Performance: Electronic design ensures accurate fault detection
  • Cost-Effective: Combines RCD and MCB functions in one unit
  • Future-Ready: Upgradeable breaking capacity
  • Versatile: Suitable for diverse applications
  • Safety Certified: Meets international electrical standards

Ideal for:

  • Home electrical safety upgrades
  • Commercial power distribution
  • Equipment protection circuits
  • Building maintenance systems
  • Electrical panel modernization

Выбор способа доставки

Вопрос 1: Интересно, принимаете ли вы небольшие заказы?

Ответ 1: Не беспокойтесь. Не стесняйтесь связываться с нами, чтобы получать больше заказов и предоставлять нашим клиентам больше удобства ,Мы принимаем небольшие заказы.

Вопрос 2: Можете ли вы отправить продукцию в мою страну?

Ответ 2: Конечно, мы можем. Если у вас нет собственного экспедитора, мы можем помочь вам.

Вопрос 3: Можете ли вы сделать OEM для меня?

Ответ 3: Мы принимаем все заказы OEM,просто свяжитесь с нами и предоставьте ваш дизайн, мы предложим вам разумную цену и сделаем образцы как можно скорее.

Вопрос 4: What’s your payment terms ?

A4: By T/T,LC AT SIGHT,30% deposit in advance, balance 70% against the copy of B/L.

Q5: How can I place the order?

A5: First sign the PI,pay deposit,then we will arrange the production.After the goods finished production we will send u the copy of B/L then u paid. Finally u will get the goods.

Q7: When can I get the quotation ?

A7: We usually quote you within 24 hours after we get your inquiry. If you are very urgent to get the quotation.Please call us or tell us in your mail, so that we could regard your inquiry priority.