ZSR3-1 RCBO - Compact 1P+N Protection (6-50A, 10кА, Type A/AC)

Основные характеристики:

  • All-in-one safety - Combines RCD (30/100/300mA) + MCB in single module

  • Type A detection - Catches AC + pulsating DC faults (ideal for EV/solar)

  • High 10kA breaking - Reliable protection for demanding installations

  • B/C tripping curves - B (3-5x) for homes, C (5-10x) for industrial loads

  • Full isolation - Switches both Live & Neutral for complete circuit disconnect

Technical Highlights:

  • Current range: 6A-50A (6,10,16,20,25,32,40,50A)

  • Electronic trip mechanism

  • Neutral switching for fast installation

  • 1P+N space-saving design

  • IEC/EN 61009-1 certified

Why Choose ZSR3-1?
✔ Space-efficient - Replaces two devices in one
✔ Future-proof - Type A handles modern electronics
✔ Industrial-grade - 10kA capacity for tough environments
✔ Easy install - Neutral switching saves time

Perfect For:

  • Residential consumer units

  • Commercial distribution boards

  • EV charging stations

  • Solar PV systems

  • High-rise building power

  • Product Details
  • Why Choose the ODL-50 RCBO
  • FAQs
  • Packing & Delivery
Introduction:

ZSR3-1 RCBO – Smart 1P+N Circuit Protection (6-50A, 10кА, Type A/AC)

Complete Electrical Safety in One Device

The ZSR3-1 RCBO combines residual current (Устройство защитного отключения (УЗО)) + overcurrent (MCB) protection in a single compact module, ensuring safety against:
✔ Earth faults (30mA/100mA/300mA sensitivity)
✔ Overloads & short circuits (B/C tripping curves)
✔ DC leakage risks (Type A detects pulsating DC – essential for EV/solar systems)

Key Advantages

🔹 Full L+N Disconnection – Works even if wiring is reversed
🔹 Electronic Filtering – Prevents false tripping from power surges
🔹 10kA Breaking Capacity – Handles high fault currents
🔹 Space-Saving 1P+N Design – More room in enclosures for easier wiring
🔹 Neutral Switching – Faster installation & testing

Technical Highlights
  • Type A/AC Options – Type A for DC-sensitive circuits (EV/solar), Type AC for standard AC

  • B & C Curves – B (3-5x In) for homes, C (5-10x In) for commercial/industrial

  • Rated Currents – 6A to 50A (6,10,16,20,25,32,40,50A)

  • Certified Safety – Complies with IEC/EN 61009-1, AS/NZS 61009.1

Why Installers & Engineers Choose ODL-50?

✅ No Nuisance Tripping – Stable performance in mission-critical circuits
✅ Safer Testing – No need to disconnect L/N during checks
✅ Fault Isolation – Only the faulty circuit shuts off, keeping others live
✅ Future-Ready – Protects modern electronics & renewable energy systems

Best Applications

🏠 Homes – Prevents shocks & fires
🏢 Commercial Buildings – Handles fluorescent lighting & motors
🔌 EV Chargers – Type A ensures DC leakage protection
☀️ Solar Systems – Reliable performance with inverters

Product Description:

ZSR3-1 RCBO – Compact 1P+N Protection (2-40A, 6кА, Type A/AC)

Complete Safety Solution:
✔ Combines RCD (30/100mA) + MCB in single module
✔ Type A (AC+DC) or Type AC protection
✔ 6kA breaking capacity with B/C tripping curves

Основные характеристики:

  • 2A to 40A current range (2,6,10,16,20,25,32,40A)

  • Full L+N disconnection for complete isolation

  • Neutral switching for faster installation/testing

  • Clear ON/OFF indicator (Green=OFF, Red=ON)

  • 35mm DIN rail mounting (EN 60715)

Technical Specifications:

  • Voltage: 110V/230V AC (1Фаза+Ноль)

  • 6kV impulse withstand

  • 20,000 mechanical operations

  • IP20 protection

  • Operating temp: -5°C to +40°C

Installation:

  • Top/bottom wiring options

  • Accepts 25mm² cable (18-3 AWG)

  • 2.5N·m tightening torque

Certified: IEC/EN/AS/NZS 61009-1

Best for: Homes, EV chargers, solar systems

CategoryParameterSpecification
StandardComplianceIEC/EN 61009-1
Electrical FeaturesRated Current (In)6,10,16,20,25,32,40,50A
TypeElectronic
Leakage Detection TypeType A or AC
Poles1Фаза+Ноль (Switched Live and Neutral)
Rated Voltage (Ue)230/240V
Sensitivity (IΔn)30mA,100mA,300mA
Insulation Voltage (Ui)500V
Frequency50/60Hz
Breaking Capacity10кА
Residual Making/Breaking Capacity (IΔm)3000A
Impulse Withstand Voltage (1.2/50μs)4000V
Trip Time (IΔn)≤0.1s
Pollution Degree2
Tripping CharacteristicB, C Curve
Mechanical FeaturesElectrical Life2,000 operations
Mechanical Life2,000 operations
Contact IndicatorYes
Protection DegreeIP20
Reference Temperature30°C
Operating Temperature-5°C to +40°C
Storage Temperature-25°C to +70°C
InstallationTerminal TypeCable/Pin-type busbar
Top Terminal (Cable)10mm²
Bottom Terminal (Cable)16mm² / 18-8 AWG
Bottom Terminal (Busbar)10mm² / 18-8 AWG
Tightening Torque2.5N·m / 22 In-lbs
Mounting35mm DIN Rail (EN 60715)
ConnectionFrom bottom

ODL-50 Dimensions

Single Module Mini RCBO with Switched Live and Neutral 6kA  JCR1-40_1 (1)

Why use Miniature RCBOs?
RCBO (Residual Current Circuit Breakers with Overcurrent Protection) devices are a combination of an RCD (Residual Current Device) and MCB (Miniature Circuit Breaker) in one.
An RCD detects Earth Leakage, i.e. current flowing where it shouldn’t, switching the circuit off where there is an Earth fault current. The RCD element of the RCBO is there to protect people.
In housing installations it’s not unusual to find that one or more RCDs are used alongside MCBs in the consumer unit, all grouped together protecting multiple circuits. What commonly happens when there is an earth fault on one circuit is that a whole group of circuits, including healthy circuits, are switched off.
In these instances, using RCDs and MCBs in groups goes against specific aspects of the IET’s 17th Edition Wiring Regulations. Specifically, Chapter 31-Division of Installation, regulation 314.1, which requires every installation to be divided into circuits as necessary –
1)To avoid danger in the event of a fault
2)To facilitate safe inspection, testing and maintenance
3)To take account of hazards that might arise from the failure of a single circuit e.g. lighting circuit
4)To reduce the possibility of unwanted tripping of RCDs (not due to fault)

Why Choose the ODL-50 RCBO?

1. Comprehensive Protection in a Single Device

✅ Combines RCD (Earth Leakage) + MCB (Overload/Short-Circuit) Protection

  • Space-saving 1P+N design reduces panel clutter

  • Тип A (AC+DC Detection) for EV chargers, solar inverters, and electronics with DC components

  • Type AC for standard AC circuits

✅ High 10kA Breaking Capacity

  • Handles industrial-level fault currents for reliable protection

✅ B/C Tripping Curves

  • B Curve (3-5x In) – Ideal for homes (lighting, sockets)

  • C Curve (5-10x In) – Best for commercial/industrial loads (motors, fluorescent lighting)


2. Superior Reliability & Safety Compliance

🔹 Electronic Trip Mechanism – Resists nuisance tripping from power surges
🔹 Full L+N Disconnection – Works even if wiring is reversed
🔹 Ultra-Fast Tripping (≤0.1s at 30mA) – Prevents electric shocks
🔹 IP20 Rated – Safe for standard enclosures
🔹 Wide Temp Range (-25°C to +70°C) – Suitable for harsh environments


3. Easy Installation, Faster Commissioning

🔧 Bottom Wiring – Simplifies connections
🔧 35mm DIN Rail Mounting – Fits standard panels
🔧 Neutral Switching – Enables testing without disconnecting wires
🔧 10mm²/16mm² Terminals – Supports thick cables


4. Ideal Applications

🏠 Homes – Shock protection for families
🏢 Commercial/Industrial – Motors, HVAC, LED lighting
🔌 EV Chargers – Type A detects DC leakage (critical for EVs)
☀️ Solar Systems – Handles DC fault currents


Key Advantages

✔ All-in-One Design – Saves space & cost
✔ Type A/AC Options – Future-proof for modern tech
✔ 10kA Industrial Protection – Highest safety standard
✔ Quick Install – Bottom entry + DIN rail
✔ Global Certifications – IEC/EN 61009-1 compliant

SEO Keywords:
Type A RCBO, 10kA circuit breaker, 1P+N RCD+MCB, EV charger protection, solar-ready RCBO


Perfect For: Electricians, OEMs, solar installers, EV charging providers

Вопрос 1: Интересно, принимаете ли вы небольшие заказы?

Ответ 1: Не беспокойтесь. Не стесняйтесь связываться с нами, чтобы получать больше заказов и предоставлять нашим клиентам больше удобства ,Мы принимаем небольшие заказы.

Вопрос 2: Можете ли вы отправить продукцию в мою страну?

Ответ 2: Конечно, мы можем. Если у вас нет собственного экспедитора, мы можем помочь вам.

Вопрос 3: Можете ли вы сделать OEM для меня?

Ответ 3: Мы принимаем все заказы OEM,просто свяжитесь с нами и предоставьте ваш дизайн, мы предложим вам разумную цену и сделаем образцы как можно скорее.

Вопрос 4: Каковы ваши условия оплаты ?

A4: По T/T,Аккредитив при виде,30% предоплата, баланс 70% по копии коносамента.

Q5: Как я могу разместить заказ?

A5: Сначала подпишите PI,внесите депозит,затем мы организуем производство. После завершения производства товаров мы отправим вам копию коносамента, затем вы оплатите. Наконец, вы получите товар.

Q7: Когда я могу получить коммерческое предложение ?

A7: Обычно мы делаем вам предложение в течение 24 часов после получения вашего запроса. Если вам очень срочно получить предложение, пожалуйста, позвоните нам или сообщите об этом в письме, чтобы мы могли рассматривать ваш запрос в приоритетном порядке.

All of our fiber optic cable package are with export wooden drum. Indoor FTTH cable’s wooden dimension is 50x50x32cm, delivery length 3km/drum, Outdoor fiber optic cable’s wooden dimension is 110cm*110cm*70cm, 0.85CBM, can be load about 33 drums for a 20GP.Also accept custom cable drum from customers. welcome to contact us! GYTS Direct Burial Single Armored Double Sheath Fiber Optic Cable GYTS Fiber Optic Cable Picture Выбор способа доставки

Prev:

Далее:

Оставить ответ

Оставьте сообщение