Introduction:AHR3-63 Type A RCBO - Smart Protection for EV Chargers & Modern Homes (6A-63A, 30mA-300mA)
Next-Gen Electrical Safety for DC-Sensitive Installations
As modern homes increasingly adopt EV chargers, solar systems, and smart appliances, the risk of DC fault currents grows.
The AHR3-63 Type A RCBO delivers advanced protection by detecting both AC and pulsating DC leakage currents - making it
the ideal choice for EV charging stations, PME systems, and PEN fault protection.Key Benefits for Your Electrical System:✔ Type A Detection - Safeguards against dangerous DC leakage from EV chargers & electronics
✔ Dual Protection - Combines 30mA-300mA earth leakage (Устройство защитного отключения (УЗО)) + overload/short-circuit (MCB) protection
✔ Готово для зарядки электромобилей - Complies with IEC 60364-7-722 for electric vehicle installations
✔ Wide Current Range - 6A to 63A versions for everything from lighting to high-power equipment
✔ B & C Tripping Curves - B Curve (3-5x) for homes | C Curve (5-10x) for commercial use
✔ Compact Design - Saves space vs separate RCD+MCB installations
Why Type A RCBOs Are Essential TodayModern electrical systems face new risks:• EV chargers create pulsating DC currents that standard Type AC devices can't detect
• Solar inverters and variable-speed drives generate DC components
• Smart home devices increase electronic load complexity
The AHR3-63 Type A RCBO solves these challenges by:
• Detecting AC + pulsating DC faults (6mA+)
• Providing instant disconnection (<0.1s at 30mA)
• Offering true double-pole switching (L+N isolation)
Ideal Applications:🔌 EV Charging Stations – Meets all regulatory requirements
🏠 Modern Homes – Protects smart appliances & electronics
☀️ Solar Installations – Handles DC components safely
🏢 Commercial Buildings – C Curve handles motor loads
Product Description:
Основные характеристики & Преимущества✅ Electromagnetic Type – Reliable operation without electronic components
✅ Dual Protection – Устройство защитного отключения (УЗО) (30mA-300mA) + MCB (overload/short-circuit) in one unit
✅ Type A Detection – Essential for EV chargers (detects pulsating DC currents)
✅ 10kA Breaking Capacity – Handles high fault currents safely
✅ B/C Tripping Curves – B Curve for homes, C Curve for commercial applications
✅ True Double-Pole Disconnection – Isolates both Live & Neutral conductors
✅ Easy Installation – Top/bottom wiring, 35mm DIN rail mounting
✅ Neutral Switching – Reduces installation and testing time
AHR3-63 RCBO Technical Specifications| Category | Parameter | Specification |
|---|---|---|
| Standard | Compliance | IEC 61009-1, EN 61009-1 |
| Electrical | Rated Current (In) | 6,10,16,20,25,32,40,50,63A |
| Type | Electromagnetic | |
| Leakage Detection Type | Type A or AC | |
| Poles | 2 Pole (1Фаза+Ноль) | |
| Rated Voltage (Ue) | 230/240V | |
| Sensitivity (IΔn) | 30mA,100mA,300mA | |
| Insulation Voltage (Ui) | 500V | |
| Frequency | 50/60Hz | |
| Breaking Capacity | 10кА | |
| Impulse Withstand Voltage | 6kV (1.2/50μs) | |
| Tripping Time | ≤0.1s at IΔn | |
| Pollution Degree | 2 | |
| Tripping Characteristic | B, C Curve | |
| Mechanical | Electrical Life | 2,000 operations |
| Mechanical Life | 10,000 operations | |
| Contact Indicator | Yes (Green=OFF, Red=ON) | |
| Protection Degree | IP20 | |
| Reference Temperature | 30°C | |
| Operating Temperature | -5°C to +40°C | |
| Storage Temperature | -25°C to +70°C | |
| Installation | Terminal Type | Cable/U-type/Pin-type busbar |
| Cable Size (Top/Bottom) | 25mm² / 18-3 AWG | |
| Busbar Size (Top/Bottom) | 10mm² / 18-8 AWG | |
| Tightening Torque | 2.5N·m (22 In-lbs) | |
| Mounting | 35mm DIN Rail (EN 60715) | |
| Connection Direction | Top or Bottom |
AHR3-63 Dimensions

EV Charger RCD Requirements: Complete Guide for Safe Installation
Do EV Chargers Need RCD Protection?
✅ Yes! According to Regulation 722.531.3, all electric vehicle chargers must be protected by:
• A 30mA RCD (Residual Current Device)
• Full disconnection of both Live & Neutral conductors
⚠️ Single-pole RCBOs are NOT suitable for EV charger installations
Understanding RDC-DD in EV Chargers
What is RDC-DD?
RDC-DD (Residual Direct Current - Disconnecting Device) is:
• Built into many modern EV chargers
• Monitors DC leakage currents on the AC side
• Automatically disconnects if dangerous DC levels are detected
Choosing the Right RCD for Your EV Charger
Option 1: EV Charger WITHOUT RDC-DD
🔹 Требуемый УЗО: Тип B
🔹 Почему? Тип B обнаруживает:
• токи утечки постоянного тока (стандартный)
• Гладкие неисправности постоянного тока (которые Тип A не может обнаружить)
Option 2: Зарядное устройство EV С RDC-DD (6обнаружение мА)
🔹 Требуемый УЗО: Тип A (наиболее экономичное)
🔹 Почему?
• Тип A работает безопасно при ≤6 мА утечки постоянного тока (RDC-DD справляется с большими неисправностями постоянного тока)
• Большинство зарядных устройств EV сейчас включают RDC-DD, делая Тип A стандартным выбором
⚠️ Предупреждение:
• Если утечка постоянного тока превышает 6 мА, УЗО типа A может не сработать
• Никогда не используйте Тип AC – оно вообще не может обнаруживать неисправности постоянного тока!
Лучшие практики установки УЗО
Где установить?
✔ Распределительный щиток (Предпочтительно) – Обеспечивает полную защиту цепи
✔ Близко к зарядному устройству EV (Альтернатива) – Требуется, если нет места в основном щите
Критическая проверка!
🔎 Существующий тип УЗО?
• В старых установках могут использоваться УЗО типа AC
• Если зарядное устройство EV использует цепь вместе с Тип AC:
ο токи утечки постоянного тока могут "слепить" УЗО
ο Другие цепи теряют защиту
ο Риск поражения электрическим током или пожара
💡 Решение:
• Обновите до типа A/B для цепей электромобиля
• Рекомендуется отдельная цепь для зарядного устройства EV
Основные моменты безопасности зарядного устройства EV| Сценарий | Правильный тип УЗО | Примечания |
|---|---|---|
| Без УЗО-DD | Тип B | Обязательно для защиты от постоянного тока |
| С УЗО-DD (6mA) | Тип A | Наиболее распространённый & Экономически эффективный |
| Старые установки | Проверьте тип! | Замените тип AC на тип A/B |
Почему это важно?⚡ Предотвращает поражение электрическим током (30Защита мА)
🔥 Снижает риск пожара (Обнаружение постоянного тока)
🚗 Обеспечивает безопасную зарядку EV (Соответствие стандартам IEC 60364)Нужна помощь в выборе правильного УЗО? Обратитесь к сертифицированному электрику для Безопасной установки зарядного устройства EV!
S-Mark & Производитель RCBO KEMA | ZHISHUN ELECTRICTRIC

















WeChat