E-mail: orcbo@orcbo.com


  ZSR3-1,18mm Módulo único RCBO, 6KA, 1P+N 10mA, Disyuntor con capacidad de alimentación doble

RCBO/

ZSR3-1,18mm Módulo único RCBO, 6KA, 1P+N 10mA, Disyuntor con capacidad de alimentación doble

ZSR3-1 RCBO - Smart Circuit Protection by ZHISHUN

Premium Safety Features

  • Dual Protection: Combines RCD (earth leakage) + MCB (overload/short-circuit)
  • Wide Current Range: 6A-40A (6,10,16,20,25,32,40Un)
  • Type A/AC Detection: Catches AC + pulsating DC faults (ideal for EV chargers)
  • 30mA/100mA/300mA Sensitivity: Personal shock & fire protection
  • 6kA Breaking Capacity: Reliable fault interruption

Technical Highlights

  • Standards: IEC61009-1, CE, CB certified
  • Voltage: 230/240V AC
  • Tripping Curves: B (3-5x In) / C (5-10x In)
  • Operating Temp: -25°C to +40°C
  • Compact 1P Design: Space-saving installation
  • Bottom Wiring: Easy connection

Why Choose ZSR3-1?
✔ All-in-one safety - No need for separate RCD+MCB
✔ EV charger ready - Type A detects DC leakage
✔ Global certifications - Meets international standards

Best for:
• Homes
• EV Stations
• Solar Systems
• Commercial Buildings

  • Product Details
  • Why Choose OSR2-40 RCBO
  • Packing & Delivery
  • FAQs
Porduct Overview

ZSR3-1 1P+N RCBOAdvanced Circuit Protection SolutionCore Protection Features:

• Single-module design combining RCD + MCB protection
• Comprehensive coverage against:
ο Short-circuit currents
ο Overload conditions
ο Earth fault currents (10/30/100/300mA sensitivity)
ο Indirect/direct contact hazards
• Built-in supply neutral wire for enhanced safety

Technical Advantages:

Superior Fault ProtectionNeutral wire ensures reliable earth fault and overcurrent detection
Critical Environment ReadyIdeal for medical facilities and sensitive electronic installations
Regulation CompliantMeets strict industry requirements for functional earth wiring
Installation EfficiencySimplified wiring saves valuable installation time
Space-Saving DesignCompact 1P+N configuration optimizes panel space

Optimal Applications:

Healthcare facilities and medical equipment
Laboratory and research environments
Data centers and server rooms
Industrial control systems
Industrial control systems

Key Benefits:
✔ Dual-function protection in one device
✔ Neutral wire enhances system reliability
✔ Meets stringent safety regulations
✔ Quick and easy installation process
✔ Compact footprint saves space

OSR2-40 RCBO Technical Specifications
CategoryParameterSpecification
CertificationStandardIEC/EN61009-1
Protection TypesGround FaultElectronic trip
Overcurrent/Short CircuitThermo-magnetic trip
Over-voltageSelectable
ElectricalLeakage Protection TypeAC, Un
Poles1P+N (1 module)
Neutral LineDisconnected
Rated Current (In)6,10,16,20,25,32,40Un
Sensitivity (IΔn)10,30,100,300mA
Trip Time (IΔn)≤0.1s
Rated Voltage (Ue)230/240V~
Frequency50/60Hz
Breaking Capacity6,000Un
Impulse Withstand Voltage4,000V (1.2/50μs)
Dielectric Test Voltage2kV (1 min)
TrippingThermal Release(1.13-1.45) x In
Magnetic ReleaseB:3-5x In, C:5-10x In
MechanicalElectrical Life4,000 cycles
Mechanical Life10,000 cycles
Contact IndicatorYes
Protection DegreeIP20
EnvironmentalOperating Temperature-25℃ to +40℃
HumidityMax 95%
InstallationTerminal TypeCable/Pin-type busbar
Max Cable SizeL(in):25mm², N/L(out):16mm²
Tightening TorqueL(in):2.5N·m, N/L(out):2N·m
Mounting35mm DIN rail
ConnectionBottom only

Key Features of This Table:

Dimensions

1. All-in-One Protection

  • Combines RCD (earth leakage) + MCB (overcurrent/short-circuit) protection in a single compact module
  • Covers: short circuits, overloads, earth faults, and direct/indirect contact risks

2. Enhanced Safety with Neutral Wire

  • Built-in neutral disconnection ensures reliable protection against earth faults and overcurrents
  • Critical for medical facilities, labs, and sensitive electronics where safety is paramount

3. Flexible Sensitivity Options

  • 10mA/30mA/100mA/300mA versions available:
    • 30mA: Personal shock protection
    • 100mA/300mA: Fire prevention

4. Compliant & Reliable

  • Meets IEC/EN61009-1 standards
  • Certified for use in regulated environments (healthcare, industrial, etc.)

5. Easy Installation

  • 1P+N design saves space in distribution boards
  • Bottom wiring for faster, cleaner installations

Best For:

  • Hospitals & Medical Equipment – Ensures uninterrupted power for critical devices
  • Data Centers – Protects servers from electrical faults
  • Industrial Controls – Handles motor inrush currents (C-curve)
  • Labs & Precision Electronics – Prevents leakage-induced interference

Key Benefits:

Space-saving – No need for separate RCD+MCB
Safety-first – Neutral wire adds extra protection layer
Versatile – Multiple sensitivity options for different needs
Quick setup – Simplified wiring reduces installation time

Shipping choice

Q1: Wonder if you accept small orders?

A1: Do not worry. Feel free to contact us .in order to get more orders and give our clients more convenient ,we accept small order.

Q2: Can you send products to my country?

A2: Sure, we can. If you do not have your own ship forwarder, we can help you.

Q3: Can you do OEM for me?

A3: We accept all OEM orders,just contact us and give me your design.we will offer you a reasonable price and make samples for you ASAP.

Q4: What’s your payment terms ?

A4: By T/T,LC AT SIGHT,30% deposit in advance, balance 70% against the copy of B/L.

Q5: How can I place the order?

A5: First sign the PI,pay deposit,then we will arrange the production.After the goods finished production we will send u the copy of B/L then u paid. Finally u will get the goods.

Q7: When can I get the quotation ?

A7: We usually quote you within 24 hours after we get your inquiry. If you are very urgent to get the quotation.Please call us or tell us in your mail, so that we could regard your inquiry priority.

Prev:

Next:

Leave a Reply

Deja un mensaje