Correo electrónico: orcbo@orcbo.com


ZSR7-1, RCBO 10kA, Tipo magnéticoA, Disyuntor operado por corriente residual, 2Poste, 1P+N - S-Mark & Fabricante de RCBO KEMA | ZHISHUN ELECTRIC

RCBO/

ZSR7-1, RCBO 10kA, Tipo magnéticoA, Disyuntor operado por corriente residual, 2Poste, 1P+N

ZSR7-1 RCBO - Smart Electronic Protection for Modern Electrical Installations

Comprehensive Circuit Protection Solution
The OSR7-40 electronic RCBO delivers advanced residual current and overcurrent protection in a single compact device, designed for superior performance in:

  • Residential complexes
  • Commercial establishments
  • Industrial facilities
  • High-rise buildings

Key Technical Features:

✔ Dual Protection System

  • 30mA/100mA/300mA residual current detection (RCD)
  • Overload and short-circuit protection (MCB)
  • Electronic tripping mechanism for precise operation

✔ Flexible Configuration Options

  • Standard 6kA breaking capacity (upgradeable to 10kA)
  • Current ratings: 6A to 40A (multiple options)
  • B and C tripping characteristics available
  • Type A (AC+DC) or Type AC versions

✔ Enhanced Safety Design

  • Complete double-pole circuit isolation
  • Neutral pole switching for efficient installation
  • Complies with IEC 61009-1 & EN61009-1 standards

Installation Advantages:

  • Space-saving single-module design
  • Simplified wiring with neutral switching
  • Compatible with standard distribution boards
  • Easy integration into existing systems

ZSR7-1 RCBO Key Specifications

  • Protection Type: Electronic
  • Breaking Capacity: 6Ka (10kA upgrade available)
  • Rated Current: 6A-40A (6,10,16,20,25,32,40Un)
  • Tripping Curves: B, C
  • Sensibilidad: 30mA/100mA/300mA
  • Detection Type: Type A/AC
  • Normas: IEC 61009-1, EN61009-1
  • Operating Voltage: 230/240V AC
  • Protection Class: IP20

  • Detalles del producto
  • Why Choose OSR7-40 RCBO
  • Empaque y entrega
  • Preguntas frecuentes
ZSR7-1 RCBO | Electronic Type A/AC Circuit Breaker (6-40Un) | 6kA/10kA Protection
Advanced Dual Protection for Electrical Safety
The ZSR7-1 RCBO combines residual current (RCD) and overcurrent (MCB) protection in one compact device, ensuring complete safety against:
• Earth leakage faults (30mA/100mA/300mA sensitivity)
• Circuit overloads & short circuits (B/C tripping curves)
• DC current risks (Type A version for EV/solar applications)
Key Benefits for Installers & Homeowners
 Full Neutral+Phase Disconnection – Works even if wiring is reversed
Electronic Filtering – Prevents false tripping from voltage spikes
Type A & AC Options – Type A detects pulsating DC (essential for EV chargers)
Wide Current Range 6A to 40A (residential/commercial use)
6kA Breaking Capacity – Upgradeable to 10Ka for high-demand systems
Test Button Included – Easy safety verification

Technical Specifications
FeatureSpecification
TipoElectronic RCBO
ProtectionEarth leakage + Overload/Short-circuit
Rated Current6Un, 10Un, 16Un, 20Un, 25Un, 32Un, 40Un
Voltage110V (low voltage) / 230V-240V
Sensibilidad30mA (personal), 100mA/300mA (fire protection)
Tripping CurveB Curve (3-5x In) / C Curve (5-10x In)
Breaking Capacity6Ka (10kA upgrade available)
DisconnectionDouble-pole (L+N)
NormasIEC 61009-1, EN 61009-1

Why Choose ZSR7-1?
🏠 For Homes
Prevents electric shocks (30mA sensitivity)
Stops electrical fires from faulty wiring
 
🔌 For EV Chargers & Solar
Type A version detects DC leakage currents
Complies with EV installation regulations
🏢 For Commercial Use
C Curve handles motor/compressor startups
100mA/300mA options reduce fire risks
Descripción del producto:
ZSR7-1 RCBO | Electromagnetic Type A/AC Circuit Breaker (6-40Un) | 6kA/10kA Protection

Complete Electrical Protection for Modern InstallationsThe ZSR7-1 electromagnetic RCBO delivers dual safety by combining earth leakage protection (RCD) and overcurrent protection (MCB) in one compact device. Ideal for residential, commercial, and industrial applications where reliable circuit protection is critical.

Key Safety Features
✔ Double-Pole DisconnectionSimultaneously cuts both Live & Neutral
✔ Type A DetectionCatches pulsating DC faults (essential for EV chargers)
✔ 6kA Breaking CapacityUpgradeable to 10kA for demanding installations
✔ B/C Tripping CurvesB Curve (3-5x In) for homes | C Curve (5-10x In) for industry
✔ 30mA/100mA/300mA SensitivityPersonal shock vs. fire protection
Why Professionals Choose ZSR7-1?
✅ Neutral SwitchingFaster installation/testing
✅ Insulated OpeningsSafer busbar connections
✅ Universal CompatibilityWorks with all standard screwdrivers
✅ Visual IndicatorsClear ON/OFF status (Red/Green)
✅ Flexible WiringTop or bottom cable entry
Ideal Applications

• EV Charging Stations (Type A version)
• Solar PV Systems
• Home Consumer Units
• Commercial Distribution Boards
• Industrial Control Panels
Upgrade your electrical protection today with ZSR7-1 - the smarter choice for safety-conscious installations!

Technical Specifications
CategoryParameterSpecification
CertificationStandards ComplianceIEC 61009-1, EN 61009-1
ElectricalRated Current (In)6,10,16,20,25,32,40,50,63,80Un
Device TypeElectronic
Detection TypeType A (AC+DC) / Type AC
Poles2 Poste (1P+N)
Rated Voltage (Ue)230/240V
Sensibilidad (IΔn)30mA,100mA,300mA
Insulation Voltage (Ui)500V
Frequency50/60Hz
Breaking Capacity6Ka
Impulse Withstand Voltage6kV (1.2/50μs)
Pollution Degree2
Tripping CharacteristicB, C Curve
MechanicalElectrical Life2,000 operaciones
Vida útil mecánica10,000 operaciones
Contact IndicatorSí (Visual ON/OFF)
Protection DegreeIP20
Reference Temperature30°C
Operating Temperature-5°C to +40°C
Storage Temperature-25°C to +70°C
InstalaciónTerminal TypeCable/U-type/Pin-type busbar
Cable Size (Top/Bottom)25mm² / 18-3 AWG
Busbar Size (Top/Bottom)10mm² / 18-8 AWG
Tightening Torque2.5N·m (22 In-lbs)
Montaje35mm DIN Rail (EN 60715)
Connection DirectionTop or Bottom

Dimensiones

Dimensiones

JCB2LE-80M Dimension
What is an RCBO and How Does it Work?

RCBO stands for 'Residual Current Breaker with Over-Current'. As the name suggests it protects against two types of fault and in essence combines the functionality of an MCB and RCD.
Let us first remind ourselves of those two faults:

1.Residual Current, or Earth Leakage - Occurs when there is an accidental break in a circuit through poor electrical wiring or DIY accidents such as drilling through a cable when mounting a picture hook or cutting through a cable with the lawn mower. In this instance the electricity must go somewhere and choosing the easiest route travels through the lawnmower or drill to the human causing electric shock.

2.Over-Current takes two forms:
2.1 Overload - Occurs when too many devices are in use on the circuit, drawing an amount of power which exceeds the capacity of the cable.
2.2 Short Circuit - Occurs when there is a direct connection between the live and neutral conductors. Without the resistance provided by the normal circuit integrity, electrical current rushes around the circuit in a loop and multiplies the amperage by many thousand times in just milliseconds and is considerably more dangerous than Overload.
Whereas an RCD is designed solely to protect against earth leakage and an MCB protects only against over-current, an RCBO protects against both types of fault.

  • Reliable Performance: Electronic design ensures accurate fault detection
  • Cost-Effective: Combines RCD and MCB functions in one unit
  • Future-Ready: Upgradeable breaking capacity
  • Versatile: Suitable for diverse applications
  • Safety Certified: Meets international electrical standards

Ideal for:

  • Home electrical safety upgrades
  • Commercial power distribution
  • Equipment protection circuits
  • Building maintenance systems
  • Electrical panel modernization

Opción de envío

Q1: Me pregunto si aceptan pedidos pequeños?

A1: No se preocupe. No dude en contactarnos para obtener más pedidos y ofrecer a nuestros clientes más conveniencia ,Aceptamos pedidos pequeños.

Q2: ¿Pueden enviar productos a mi país??

A2: Claro, podemos. Si no tiene su propio transportista, podemos ayudarle.

Q3: ¿Pueden hacer OEM para mí??

A3: Aceptamos todos los pedidos OEM,solo contáctenos y envíeme su diseño. Le ofreceremos un precio razonable y haremos muestras para usted lo antes posible.

Q4: What’s your payment terms ?

A4: Por T/T,LC A LA VISTA,30% depósito por adelantado, saldo 70% contra la copia del B/L.

Q5: ¿Cómo puedo hacer el pedido??

A5: Primero firme el PI,pague el depósito,luego organizaremos la producción. Después de que los productos terminen la producción, le enviaremos la copia del B/L y luego usted pagará. Finalmente recibirá los productos.

Q7: ¿Cuándo puedo obtener la cotización? ?

A7: Normalmente le cotizamos dentro de 24 horas después de recibir su consulta. Si tiene mucha urgencia de recibir la cotización, por favor llámenos o díganos en su correo, para que podamos dar prioridad a su consulta.