Principais Características:

  • All-in-one safety - Combina DDR (30/100/300mA) + MCB in single module

  • Type A detection - Detecta falhas AC + DC pulsante (ideal for EV/solar)

  • High 10kA breaking - Reliable protection for demanding installations

  • B/C tripping curves - B (3-5x) for homes, C (5-10x) for industrial loads

  • Full isolation - Switches both Live & Neutral for complete circuit disconnect

Destaques Técnicos:

  • Current range: 6A-50A (6,10,16,20,25,32,40,50A)

  • Electronic trip mechanism

  • Neutral switching for fast installation

  • 1P+N space-saving design

  • IEC/EN 61009-1 certified

Porquê Escolher ZSR3-1?
Space-efficient - Replaces two devices in one
Future-proof - Type A handles modern electronics
Industrial-grade - 10kA capacity for tough environments
Easy install - Neutral switching saves time

Perfect For:

  • Residential consumer units

  • Commercial distribution boards

  • Estações de carregamento de VE

  • Solar PV systems

  • High-rise building power

  • Detalhes do Produto
  • Why Choose the ODL-50 RCBO
  • FAQs
  • Embalagem & Entrega
Introduction:

ZSR3-1 RCBO – Smart 1P+N Circuit Protection (6-50A, 10kA, Type A/AC)

Complete Electrical Safety in One Device

The ZSR3-1 RCBO combina residual current (RCD) + overcurrent (MCB) protection in a single compact module, ensuring safety against:
Earth faults (30mA/100mA/300mA sensitivity)
Overloads & short circuits (B/C tripping curves)
DC leakage risks (Type A detects pulsating DC – essential for EV/solar systems)

Principais Vantagens

🔹 Full L+N Disconnection – Works even if wiring is reversed
🔹 Electronic Filtering – Prevents false tripping from power surges
🔹 10Capacidade de Corte kA – Handles high fault currents
🔹 Space-Saving 1P+N Design – More room in enclosures for easier wiring
🔹 Neutral Switching – Faster installation & testing

Destaques Técnicos
  • Type A/AC Options – Type A for DC-sensitive circuits (EV/solar), Type AC for standard AC

  • B & C Curves – B (3-5x In) for homes, C (5-10x In) for commercial/industrial

  • Correntes Nominais – 6A to 50A (6,10,16,20,25,32,40,50A)

  • Certified Safety – Complies with IEC/EN 61009-1, AS/NZS 61009.1

Why Installers & Engineers Choose ODL-50?

No Nuisance Tripping – Stable performance in mission-critical circuits
Safer Testing – No need to disconnect L/N during checks
Fault Isolation – Only the faulty circuit shuts off, keeping others live
Future-Ready – Protects modern electronics & renewable energy systems

Best Applications

🏠 Homes – Prevents shocks & fires
🏢 Commercial Buildings – Handles fluorescent lighting & motores
🔌 EV Chargers – Type A ensures DC leakage protection
☀️ Solar Systems – Reliable performance with inverters

Product Description

ZSR3-1 RCBO – Compact 1P+N Protection (2-40A, 6kA, Type A/AC)

Complete Safety Solution:
✔ Combines RCD (30/100mA) + MCB in single module
✔ Type A (AC+DC) or Type AC protection
✔ 6kA breaking capacity with B/C tripping curves

Principais Características:

  • 2A to 40A current range (2,6,10,16,20,25,32,40A)

  • Full L+N disconnection for complete isolation

  • Neutral switching for faster installation/testing

  • Clear ON/OFF indicator (Green=OFF, Red=ON)

  • 35mm DIN rail mounting (EN 60715)

Technical Specifications:

  • Tensão: 110V/230V AC (1P+N)

  • 6kV impulse withstand

  • 20,000 mechanical operations

  • Proteção IP20

  • Operating temp: -5°C a +40°C

Instalação:

  • Top/bottom wiring options

  • Accepts 25mm² cable (18-3 AWG)

  • 2.5N·m tightening torque

Certified: IEC/EN/AS/NZS 61009-1

Melhor para: Homes, EV chargers, solar systems

CategoriaParâmetroEspecificação
NormaComplianceIEC/EN 61009-1
Electrical FeaturesRated Current (In)6,10,16,20,25,32,40,50A
TypeElectronic
Leakage Detection TypeType A or AC
Poles1P+N (Switched Live and Neutral)
Tensão Nominal (Ue)230/240V
Sensitivity (IΔn)30mA,100mA,300mA
Insulation Voltage (Ui)500V
Frequency50/60Hz
Breaking Capacity10kA
Residual Making/Breaking Capacity (IΔm)3000A
Impulse Withstand Voltage (1.2/50μs)4000V
Trip Time (IΔn)≤0.1s
Pollution Degree2
Tripping CharacteristicB, C Curve
Mechanical FeaturesElectrical Life2,000 Operações
Mechanical Life2,000 Operações
Contact IndicatorYes
Protection DegreeIP20
Reference Temperature30°C
Temperatura de Operação-5°C a +40°C
Temperatura de Armazenamento-25°C a +70°C
InstalaçãoTipo de TerminalBarra colectora tipo Cabo/Pino
Top Terminal (Cable)10mm²
Bottom Terminal (Cable)16mm² / 18-8 AWG
Bottom Terminal (Busbar)10mm² / 18-8 AWG
Torque de Aperto2.5N·m / 22 lb-pol
Montagem35mm DIN Rail (EN 60715)
LigaçãoFrom bottom

ODL-50 Dimensions

Single Module Mini RCBO with Switched Live and Neutral 6kA  JCR1-40_1 (1)

Why use Miniature RCBOs?
RCBO (Residual Current Circuit Breakers with Overcurrent Protection) devices are a combination of an RCD (Residual Current Device) and MCB (Miniature Circuit Breaker) in one.
An RCD detects Earth Leakage, i.e. current flowing where it shouldn’t, switching the circuit off where there is an Earth fault current. The RCD element of the RCBO is there to protect people.
In housing installations it’s not unusual to find that one or more RCDs are used alongside MCBs in the consumer unit, all grouped together protecting multiple circuits. What commonly happens when there is an earth fault on one circuit is that a whole group of circuits, including healthy circuits, are switched off.
In these instances, using RCDs and MCBs in groups goes against specific aspects of the IET’s 17th Edition Wiring Regulations. Specifically, Chapter 31-Division of Installation, regulation 314.1, which requires every installation to be divided into circuits as necessary –
1)To avoid danger in the event of a fault
2)To facilitate safe inspection, testing and maintenance
3)To take account of hazards that might arise from the failure of a single circuit e.g. lighting circuit
4)To reduce the possibility of unwanted tripping of RCDs (not due to fault)

Why Choose the ODL-50 RCBO?

1. Comprehensive Protection in a Single Device

Combina DDR (Earth Leakage) + MCB (Overload/Short-Circuit) Protection

  • Poupa espaço 1P+N design reduces panel clutter

  • Tipo A (AC+DC Detection) for EV chargers, inversores solares, and electronics with DC components

  • Type AC for standard AC circuits

High 10kA Breaking Capacity

  • Handles industrial-level fault currents for reliable protection

B/C Tripping Curves

  • B Curve (3-5x In) – Ideal for homes (iluminação, sockets)

  • C Curve (5-10x In) – Best for commercial/industrial loads (motores, fluorescent lighting)


2. Superior Reliability & Safety Compliance

🔹 Electronic Trip Mechanism – Resists nuisance tripping from power surges
🔹 Full L+N Disconnection – Works even if wiring is reversed
🔹 Ultra-Fast Tripping (≤0.1s at 30mA) – Prevents electric shocks
🔹 IP20 Rated – Safe for standard enclosures
🔹 Wide Temp Range (-25°C a +70°C) – Suitable for harsh environments


3. Instalação fácil, Faster Commissioning

🔧 Ligação Inferior – Simplifies connections
🔧 35Montagem em calha DIN mm – Fits standard panels
🔧 Neutral Switching – Enables testing without disconnecting wires
🔧 10mm²/16mm² Terminals – Supports thick cables


4. Aplicações Ideais

🏠 Homes – Shock protection for families
🏢 Commercial/Industrial – Motores, HVAC, LED lighting
🔌 EV Chargers – Type A detects DC leakage (critical for EVs)
☀️ Solar Systems – Handles DC fault currents


Principais Vantagens

All-in-One Design – Saves space & cost
Type A/AC Options – Future-proof for modern tech
10kA Industrial Protection – Highest safety standard
Quick Install – Bottom entry + DIN rail
Global Certifications – IEC/EN 61009-1 conforme

SEO Keywords:
Type A RCBO, 10kA circuit breaker, 1P+N RCD+MCB, EV charger protection, solar-ready RCBO


Perfect For: Electricians, OEMs, solar installers, EV charging providers

P1: Gostaria de saber se aceitam pequenas encomendas?

R1: Não se preocupe. Sinta-se à vontade para nos contactar para obter mais encomendas e dar mais conveniência aos nossos clientes ,Aceitamos pequenas encomendas.

P2: Podem enviar produtos para o meu país?

R2: Claro, Podemos. Se não tiver o seu próprio transitário, Podemos ajudá-lo.

P3: Podem fazer OEM para mim?

R3: Aceitamos todas as encomendas OEM,Basta contactar-nos e enviar-nos o seu design. Nós ofereceremos um preço razoável e faremos amostras para si o mais rápido possível.

P4: Quais são os termos de pagamento ?

R4: Por T/T,LC à vista,30% Depósito antecipado, Saldo 70% Contra cópia do B/L.

P5: Como posso fazer a encomenda?

R5: Primeiro assine o PI,Pague o depósito,então organizaremos a produção. Após a produção das mercadorias, enviaremos a cópia do B/L e depois efetuará o pagamento. Finalmente receberá as mercadorias.

Q7: Quando posso receber a cotação ?

A7: Normalmente fazemos a cotação dentro de 24 horas após recebermos a sua consulta. Se tiver muita urgência em obter o orçamento, por favor ligue-nos ou diga-nos no seu e-mail, para que possamos considerar a sua consulta como prioritária.

All of our fiber optic cable package are with export wooden drum. Indoor FTTH cable’s wooden dimension is 50x50x32cm, delivery length 3km/drum, Outdoor fiber optic cable’s wooden dimension is 110cm*110cm*70cm, 0.85CBM, can be load about 33 drums for a 20GP.Also accept custom cable drum from customers. welcome to contact us! GYTS Direct Burial Single Armored Double Sheath Fiber Optic Cable GYTS Fiber Optic Cable Picture Escolha de envio

Anterior:

Seguinte:

Deixar uma resposta

Deixe uma mensagem