ZSR3-1,Modulo singolo Mini RCBO,10kA, Tipo A, RCCB con protezione contro sovracorrente,1P+N - S-Mark & Produttore KEMA RCBO | ZHISHUN ELECTRIC

RCBO/

ZSR3-1,Modulo singolo Mini RCBO,10kA, Tipo A, RCCB con protezione contro sovracorrente,1P+N

ZSR3-1 RCBO - Compact 1P+N Protection (6-50A, 10kA, Type A/AC)

Key Features:

  • All-in-one safety - Combines RCD (30/100/300mA) + MCB in modulo singolo

  • Type A detection - Catches AC + pulsating DC faults (ideal for EV/solar)

  • High 10kA breaking - Reliable protection for demanding installations

  • B/C tripping curves - B (3-5x) for homes, C (5-10x) for industrial loads

  • Full isolation - Switches both Live & Neutral for complete circuit disconnect

Caratteristiche Tecniche:

  • Current range: 6A-50A (6,10,16,20,25,32,40,50A)

  • Electronic trip mechanism

  • Neutral switching for fast installation

  • 1P+N space-saving design

  • IEC/EN 61009-1 certificato

Why Choose ZSR3-1?
Space-efficient - Replaces two devices in one
Future-proof - Type A handles modern electronics
Industrial-grade - 10kA capacity for tough environments
Easy install - Neutral switching saves time

Perfect For:

  • Residential consumer units

  • Commercial distribution boards

  • Stazioni di ricarica EV

  • Solar PV systems

  • High-rise building power

  • Dettagli del Prodotto
  • Why Choose the ODL-50 RCBO
  • Domande Frequenti
  • Imballaggio e Consegna
Introduzione:

ZSR3-1 RCBO – Smart 1P+N Circuit Protection (6-50A, 10kA, Type A/AC)

Complete Electrical Safety in One Device

The ZSR3-1 RCBO combines residual current (RCD) + overcurrent (MCB) protection in a single compact module, ensuring safety against:
Earth faults (30mA/100mA/300mA sensitivity)
Overloads & short circuits (B/C tripping curves)
DC leakage risks (Type A detects pulsating DC – essential for EV/solar systems)

Vantaggi principali

🔹 Full L+N Disconnection – Works even if wiring is reversed
🔹 Electronic Filtering – Prevents false tripping from power surges
🔹 10kA Breaking Capacity – Handles high fault currents
🔹 Space-Saving 1P+N Design – More room in enclosures for easier wiring
🔹 Interruzione del neutro – Faster installation & testing

Caratteristiche Tecniche
  • Type A/AC Options – Type A for DC-sensitive circuits (EV/solar), Type AC for standard AC

  • B & C Curves – B (3-5x In) for homes, C (5-10x In) for commercial/industrial

  • Rated Currents – 6A to 50A (6,10,16,20,25,32,40,50A)

  • Certified Safety – Complies with IEC/EN 61009-1, AS/NZS 61009.1

Why Installers & Engineers Choose ODL-50?

No Nuisance Tripping – Stable performance in mission-critical circuits
Safer Testing – No need to disconnect L/N during checks
Fault Isolation – Only the faulty circuit shuts off, keeping others live
Future-Ready – Protects modern electronics & renewable energy systems

Best Applications

🏠 Homes – Prevents shocks & fires
🏢 Commercial Buildings – Handles fluorescent lighting & motors
🔌 EV Chargers – Type A ensures DC leakage protection
☀️ Solar Systems – Reliable performance with inverters

Descrizione del prodotto:

ZSR3-1 RCBOCompact 1P+N Protection (2-40A, 6kA, Type A/AC)

Complete Safety Solution:
✔ Combines RCD (30/100mA) + MCB in modulo singolo
✔ Type A (AC+DC) or Type AC protection
✔ 6kA breaking capacity with B/C tripping curves

Key Features:

  • 2A to 40A current range (2,6,10,16,20,25,32,40A)

  • Full L+N disconnection for complete isolation

  • Neutral switching for faster installation/testing

  • Clear ON/OFF indicator (Green=OFF, Red=ON)

  • 35mm DIN rail mounting (EN 60715)

Technical Specifications:

  • Tensione: 110V/230V AC (1P+N)

  • 6kV impulse withstand

  • 20,000 mechanical operations

  • Protezione IP20

  • Operating temp: -5°C a +40°C

Installazione:

  • Top/bottom wiring options

  • Accepts 25mm² cable (18-3 AWG)

  • 2.5N·m tightening torque

Certificato: IEC/EN/AS/NZS 61009-1

Best for: Homes, Caricabatterie EV, sistemi solari

CategoriaParametroSpecifiche
StandardComplianceIEC/EN 61009-1
Caratteristiche ElettricheCorrente Nominale (In)6,10,16,20,25,32,40,50A
TypeElettronico
Tipo di Rilevamento PerditeTipo A o AC
Poli1P+N (Switched Live and Neutral)
Tensione Nominale (Ue)230/240V
Sensibilità (IΔn)30mA,100mA,300mA
Tensione di isolamento (Ui)500V
Frequenza50/60Hz
Capacità di Interruzione10kA
Residual Making/Breaking Capacity (IΔm)3000A
Tensione di Tenuta agli Impulsi (1.2/50μs)4000V
Trip Time (IΔn)≤0.1s
Grado di Inquinamento2
Caratteristica di InterruzioneB, C Curva
Caratteristiche MeccanicheDurata Elettrica2,000 operazioni
Durata meccanica2,000 operazioni
Indicatore di Contatto
Grado di ProtezioneIP20
Temperatura di Riferimento30°C
Temperatura di Funzionamento-5°C a +40°C
Temperatura di Stoccaggio-25°C a +70°C
InstallazioneTipo di TerminaleCavo/Barra a spina
Top Terminal (Cable)10mm²
Bottom Terminal (Cable)16mm² / 18-8 AWG
Bottom Terminal (Busbar)10mm² / 18-8 AWG
Coppia di Serraggio2.5N·m / 22 In-lbs
Montaggio35Guida DIN mm (EN 60715)
ConnessioneFrom bottom

ODL-50 Dimensions

Single Module Mini RCBO with Switched Live and Neutral 6kA  JCR1-40_1 (1)

Why use Miniature RCBOs?
RCBO (Residual Current Circuit Breakers with Overcurrent Protection) devices are a combination of an RCD (Residual Current Device) and MCB (Miniature Circuit Breaker) in one.
An RCD detects Earth Leakage, i.e. current flowing where it shouldn’t, switching the circuit off where there is an Earth fault current. The RCD element of the RCBO is there to protect people.
In housing installations it’s not unusual to find that one or more RCDs are used alongside MCBs in the consumer unit, all grouped together protecting multiple circuits. What commonly happens when there is an earth fault on one circuit is that a whole group of circuits, including healthy circuits, are switched off.
In these instances, using RCDs and MCBs in groups goes against specific aspects of the IET’s 17th Edition Wiring Regulations. Specifically, Chapter 31-Division of Installation, regulation 314.1, which requires every installation to be divided into circuits as necessary –
1)To avoid danger in the event of a fault
2)To facilitate safe inspection, testing and maintenance
3)To take account of hazards that might arise from the failure of a single circuit e.g. lighting circuit
4)To reduce the possibility of unwanted tripping of RCDs (not due to fault)

Why Choose the ODL-50 RCBO?

1. Comprehensive Protection in a Single Device

Combines RCD (Earth Leakage) + MCB (Overload/Short-Circuit) Protection

  • Space-saving 1P+N design reduces panel clutter

  • Tipo A (AC+DC Detection) for EV chargers, solar inverters, and electronics with DC components

  • Type AC for standard AC circuits

High 10kA Breaking Capacity

  • Handles industrial-level fault currents for reliable protection

B/C Tripping Curves

  • B Curve (3-5x In) – Ideal for homes (lighting, sockets)

  • C Curva (5-10x In) – Best for commercial/industrial loads (motors, fluorescent lighting)


2. Superior Reliability & Safety Compliance

🔹 Electronic Trip Mechanism – Resists nuisance tripping from power surges
🔹 Full L+N Disconnection – Works even if wiring is reversed
🔹 Ultra-Fast Tripping (≤0.1s at 30mA) – Prevents electric shocks
🔹 IP20 Rated – Safe for standard enclosures
🔹 Wide Temp Range (-25°C a +70°C) – Suitable for harsh environments


3. Easy Installation, Faster Commissioning

🔧 Bottom Wiring – Simplifies connections
🔧 35mm DIN Rail Mounting – Fits standard panels
🔧 Interruzione del neutro – Enables testing without disconnecting wires
🔧 10mm²/16mm² Terminals – Supports thick cables


4. Applicazioni Ideali

🏠 Homes – Shock protection for families
🏢 Commercial/Industrial – Motori, HVAC, LED lighting
🔌 EV Chargers – Type A detects DC leakage (critical for EVs)
☀️ Solar Systems – Handles DC fault currents


Vantaggi principali

All-in-One Design – Saves space & cost
Type A/AC Options – Future-proof for modern tech
10kA Industrial Protection – Highest safety standard
Quick Install – Bottom entry + DIN rail
Global Certifications – IEC/EN 61009-1 compliant

SEO Keywords:
Type A RCBO, 10kA circuit breaker, 1P+N RCD+MCB, EV charger protection, solar-ready RCBO


Perfect For: Electricians, OEMs, solar installers, EV charging providers

Q1: Mi chiedo se accettate piccoli ordini?

A1: Non preoccuparti. Sentiti libero di contattarci per ricevere più ordini e offrire ai nostri clienti di più comodo ,accettiamo ordini di piccole dimensioni.

Q2: Puoi inviare prodotti nel mio paese?

A2: Certo, possiamo. Se non hai un tuo spedizioniero, possiamo aiutarti.

Q3: Puoi fare OEM per me?

A3: Accettiamo tutti gli ordini OEM,contattaci e consegnami il tuo design. Ti offriamo un prezzo ragionevole e prepareremo campioni per te il prima possibile.

Q4: Quali sono le vostre condizioni di pagamento ?

A4: Entro T/T,LC A VISTA,30% deposito anticipato, saldo 70% contro copia di B/L.

Q5: Come posso effettuare l'ordine?

A5: Prima firma la PI,paga il deposito,poi organizzeremo la produzione. Dopo che la merce avrà terminato la produzione, ti invieremo la copia di B/L e poi paghi. Infine riceverai la merce.

Q7: Quando posso ricevere il preventivo ?

A7: Di solito ti forniamo un preventivo entro 24 ore dopo aver ricevuto la tua richiesta. Se hai molta urgenza di ricevere il preventivo, ti preghiamo di chiamarci o dircelo nella tua mail, così potremo considerare la tua richiesta come prioritaria.

All of our fiber optic cable package are with export wooden drum. Indoor FTTH cable’s wooden dimension is 50x50x32cm, delivery length 3km/drum, Outdoor fiber optic cable’s wooden dimension is 110cm*110cm*70cm, 0.85CBM, can be load about 33 drums for a 20GP.Also accept custom cable drum from customers. welcome to contact us! GYTS Direct Burial Single Armored Double Sheath Fiber Optic Cable GYTS Fiber Optic Cable Picture Scelta di spedizione

Precedente:

Avanti:

Lascia un commento

Lascia un messaggio