AHR3-63 RCBO - Advanced Circuit Protection for Modern Electrical Systems
Product Overview:
The AHR3-63 is a premium Residual Current Circuit Breaker with Overcurrent Protection (RCBO) designed to deliver comprehensive electrical safety for residential, commerciale, and industrial applications. Its innovative dual-protection design combines earth leakage detection with overload/short-circuit protection in a single compact unit.
Key Features & Benefits:
Dual Protection Technology

  • 30mA/100mA/300mA residual current protection (RCD)
  • Overload and short-circuit protection (MCB)
  • Electromagnetic tripping mechanism for reliable operation

✔ EV Charger Ready

  • Type A version detects pulsating DC currents (essential for EV charging stations)
  • True double-pole disconnection (L+N) meets EV installation requirements

✔ Superior Performance

  • 10kA breaking capacity
  • B and C tripping curves available
  • Rated current: 6A-63A (multiple options)

✔ Installation Advantages

  • Neutral pole switching reduces commissioning time
  • Double handle design for independent control
  • 35mm DIN rail mounting
  • Top/bottom wiring options

Technical Specifications:

  • Standard: IEC 61009-1, EN 61009-1
  • Tensione Nominale: 230/240V AC
  • Tensione di isolamento: 500V
  • Durata meccanica: 10,000 operazioni
  • Grado di Protezione: IP20
  • Ambient Temperature: -5°C a +40°C

Applicazioni Ideali:

  • Residential electrical distribution
  • Commercial building power systems
  • Industrial control panels
  • EV charging installations
  • High-rise building power distribution

  • Dettagli del Prodotto
  • Why Choose AHR3-63 RCBO
  • Imballaggio e Consegna
  • Domande Frequenti
Introduzione:
AHR3-63 Type A RCBO - Smart Protection for EV Chargers & Modern Homes (6A-63A, 30mA-300mA)
Next-Gen Electrical Safety for DC-Sensitive Installations
As modern homes increasingly adopt EV chargers, sistemi solari, and smart appliances, the risk of DC fault currents grows.
The AHR3-63 Type A RCBO delivers advanced protection by detecting both AC and pulsating DC leakage currents - making it
the ideal choice for EV charging stations, PME systems, and PEN fault protection.

Key Benefits for Your Electrical System
✔ Type A Detection - Safeguards against dangerous DC leakage from EV chargers & electronics
✔ Dual Protection - Combines 30mA-300mA earth leakage (RCD) + overload/short-circuit (MCB) protection
✔ EV Charger Ready - Complies with IEC 60364-7-722 for electric vehicle installations
✔ Wide Current Range - 6A to 63A versions for everything from lighting to high-power equipment
✔ B & C Tripping Curves - B Curve (3-5x) for homes | C Curva (5-10x) for commercial use
✔ Compact Design - Saves space vs separate RCD+MCB installations
Why Type A RCBOs Are Essential Today

Modern electrical systems face new risks:
• EV chargers create pulsating DC currents that standard Type AC devices can't detect
• Solar inverters and variable-speed drives generate DC components
• Smart home devices increase electronic load complexity

The AHR3-63 Type A RCBO solves these challenges by:
• Detecting AC + pulsating DC faults (6mA+)
• Providing instant disconnection (<0.1s at 30mA)
• Offering true double-pole switching (L+N isolation)

Applicazioni Ideali:
🔌 EV Charging StationsMeets all regulatory requirements
🏠 Modern HomesProtects smart appliances & electronics
☀️ Impianti solariHandles DC components safely
🏢 Commercial BuildingsC Curve handles motor loads

Descrizione del prodotto:
Key Features & Benefits

Electromagnetic TypeReliable operation without electronic components
Dual ProtectionRCD (30mA-300mA) + MCB (overload/short-circuit) in one unit
Type A DetectionEssential for Caricabatterie EV (detects pulsating DC currents)
10kA Breaking CapacityHandles high fault currents safely
B/C Tripping CurvesB Curve for homes, C Curva for commercial applications
True Double-Pole DisconnectionIsolates both Live & Neutral conductors
Easy InstallationTop/bottom wiring, 35mm DIN rail mounting
Interruzione del neutroReduces installation and testing time
 
AHR3-63 RCBO Technical Specifications
CategoriaParametroSpecifiche
StandardComplianceIEC 61009-1, EN 61009-1
ElectricalCorrente Nominale (In)6,10,16,20,25,32,40,50,63A
TypeElectromagnetic
Tipo di Rilevamento PerditeTipo A o AC
Poli2 Polo (1P+N)
Tensione Nominale (Ue)230/240V
Sensibilità (IΔn)30mA,100mA,300mA
Tensione di isolamento (Ui)500V
Frequenza50/60Hz
Capacità di Interruzione10kA
Tensione di Tenuta agli Impulsi6kV (1.2/50μs)
Tripping Time≤0.1s at IΔn
Grado di Inquinamento2
Caratteristica di InterruzioneB, C Curva
MechanicalDurata Elettrica2,000 operazioni
Durata meccanica10,000 operazioni
Indicatore di ContattoSì (Green=OFF, Red=ON)
Grado di ProtezioneIP20
Temperatura di Riferimento30°C
Temperatura di Funzionamento-5°C a +40°C
Temperatura di Stoccaggio-25°C a +70°C
InstallazioneTipo di TerminaleCable/U-type/Pin-type busbar
Dimensione del Cavo (Alto/Basso)25mm² / 18-3 AWG
Dimensione della Barra Collettore (Alto/Basso)10mm² / 18-8 AWG
Coppia di Serraggio2.5N·m (22 In-lbs)
Montaggio35Guida DIN mm (EN 60715)
Connection DirectionTop or Bottom

AHR3-63 Dimensions

EV Charger RCD Requirements: Complete Guide for Safe Installation

Do EV Chargers Need RCD Protection?

Sì! According to Regulation 722.531.3, all electric vehicle chargers must be protected by:
A 30mA RCD (Residual Current Device)
Full disconnection of both Live & Neutral conductors

⚠️ Single-pole RCBOs are NOT suitable for EV charger installations


Understanding RDC-DD in EV Chargers

What is RDC-DD?

RDC-DD (Residual Direct Current - Disconnecting Device) is:
Built into many modern EV chargers
Monitors DC leakage currents on the AC side
Automatically disconnects if dangerous DC levels are detected

Choosing the Right RCD for Your EV Charger

Option 1: EV Charger WITHOUT RDC-DD

🔹 Required RCD: Tipo B
🔹 Why? Type B detects:
AC leakage (standard)
Guasti CC uniformi (che il Tipo A non può rilevare)
Option 2: Caricabatterie EV CON RDC-DD (6rilevamento mA)

🔹 Required RCD: Tipo A (più conveniente)
🔹 Why?
Il Tipo A funziona in sicurezza con perdite DC ≤6mA (RDC-DD gestisce guasti DC più elevati)
La maggior parte dei caricabatterie EV ora include RDC-DD, rendendo il Tipo A la scelta standard
⚠️ Avviso:
Se la perdita DC supera 6mA, un interruttore differenziale Tipo A potrebbe non scattare
Non usare mai Tipo AC – non può rilevare guasti DC!

Migliori pratiche per l'installazione dell'interruttore differenziale

Dove installare?

Quadro elettrico (Preferito) – Garantisce protezione completa del circuito
Vicino al caricabatterie EV (Alternativa) – Necessario se non c'è spazio nel quadro principale

Controllo critico!

🔎 Tipo di interruttore differenziale esistente?
Le installazioni più vecchie possono utilizzare interruttori differenziali Tipo AC
Se il caricabatterie EV condivide un circuito con Tipo AC:
  ο la perdita DC potrebbe "rendere cieco" l'interruttore differenziale
ο Altri circuiti perdono protezione
ο Rischio di scossa elettrica o incendio
💡 Soluzione:
Aggiornare a Tipo A/B per i circuiti EV
Circuito separato consigliato per il caricabatterie EV

Punti chiave per la sicurezza del caricabatterie EV
ScenarioTipo corretto di RCDNote
Nessun RDC-DDTipo BObbligatorio per la protezione contro guasti DC
Con RDC-DD (6mA)Tipo APiù comune & economico
Vecchie installazioniControllare il tipo!Sostituire il tipo AC con Tipo A/B
Perché è importante?Previene scosse elettriche (30Protezione mA)
🔥 Riduce i rischi di incendio (Rilevamento guasto DC)
🚗 Garantisce una ricarica EV sicura (Conformità con IEC 60364)Hai bisogno di aiuto per scegliere l'RCD giusto? Consulta un elettricista certificato per installazione sicura del caricabatterie EV!

Il nostro RCBO offre il perfetto equilibrio tra sicurezza e prestazioni, con:

  • Protezione certificata conforme agli standard internazionali
  • Funzionalità combinata RCD+MCB che salva spazio
  • Funzionamento affidabile in ambienti esigenti
  • Opzioni di configurazione flessibili

Compliance & Certificazione: Piena conformità con IEC 61009-1 e gli standard di sicurezza EN61009-1, garantire una protezione affidabile per le tue installazioni elettriche. Questa versione:

  1. Organizza le informazioni in sezioni chiare
  2. Evidenzia prima i principali vantaggi
  3. Utilizza un linguaggio più professionale
  4. Mantiene tutti i dettagli tecnici
  5. Migliora la leggibilità
  6. Più adatta per cataloghi di prodotti e siti web
  7. Più attraente per acquirenti professionali

Scelta di spedizione

Q1: Mi chiedo se accettate piccoli ordini? A1: Non preoccuparti. Sentiti libero di contattarci per ricevere più ordini e offrire ai nostri clienti di più comodo ,accettiamo ordini di piccole dimensioni. Q2: Puoi inviare prodotti nel mio paese? A2: Certo, possiamo. Se non hai un tuo spedizioniero, possiamo aiutarti. Q3: Puoi fare OEM per me? A3: Accettiamo tutti gli ordini OEM,contattaci e consegnami il tuo design. Ti offriamo un prezzo ragionevole e prepareremo campioni per te il prima possibile. Q4: Quali sono le vostre condizioni di pagamento ? A4: Entro T/T,LC A VISTA,30% deposito anticipato, saldo 70% contro copia di B/L. Q5: Come posso effettuare l'ordine? A5: Prima firma la PI,paga il deposito,poi organizzeremo la produzione. Dopo che la merce avrà terminato la produzione, ti invieremo la copia di B/L e poi paghi. Infine riceverai la merce. Q7: Quando posso ricevere il preventivo ? A7: Di solito ti forniamo un preventivo entro 24 ore dopo aver ricevuto la tua richiesta. Se hai molta urgenza di ricevere il preventivo, ti preghiamo di chiamarci o dircelo nella tua mail, così potremo considerare la tua richiesta come prioritaria.

Avanti:

Lascia un commento

Lascia un messaggio