ZSL1-1B Type B RCCB - Advanced Leakage Protection

Key Features:
✔ Type B Detection - AC/DC leakage protection (IEC61008-1, IEC62423)
✔ Wide Current Range - 16-100A (2P/4P configurations)
✔ Multi-Voltage Support - 110V-415V systems
✔ Precision Tripping - 30/100/300mA sensitivity
✔ Robust Design> - -25°C to +40°C operation

Technical Specs:

  • Poles: 2P(1P+N), 4P(3P+N) - N left
  • Tripping Threshold: 0.4IΔn or 10mA
  • Certifications: CE, CB, TUV, UKCA
  • Wiring: Bidirectional connection

Aplicações:

  • Industrial plants
  • Renewable energy systems
  • EV charging infrastructure

Certificados: CE, CB, TUV, UKCA

  • Product Details
  • Why Choose the ODL26-100B Type B RCCB
  • FAQs
  • Packing & Delivery
The ZSL1-1B Type B RCCB represents the next generation of residual current protection, engineered to address the complex safety challenges of today’s electrical systems. Featuring an industry-leading 100A rating and comprehensive detection capabilities for all types of leakage currents, this advanced device provides optimal protection for mission-critical applications including large-scale industrial facilities, grid-connected renewable energy installations, and high-capacity EV charging networks. By delivering superior electrical fault detection and prevention, the ZSL1-1B safeguards both human operators and sensitive equipment against potentially dangerous leakage currents in demanding operational environments.
ZSL1-1B Type B RCCB - Advanced Leakage Protection for Modern Power Systems
Key Benefits:

Full-Spectrum Protection - Detects all leakage types (AC/DC up to 1000Hz)
100A High-Capacity - Handles demanding industrial loads
Precision Detection - Responds to minute leakage currents
Industrial Durability - Built for harsh environments
Global Compliance - Meets international Type B standards
Technical Highlights:
Frequency Range: 0-1000Hz coverage
Montagem: Standard 35mm DIN rail
Visual Indicators: Clear fault status display
Materials: Heavy-duty construction

Ideal Applications:
EV Fast Charging Stations
Solar/Wind Farm Installations
Factory Automation Systems
Critical Data Centers
Medical Power Networks
Why Professionals Choose ZSL1-1B:

Future-ready protection for modern electrical challenges
Simplified maintenance with smart indicators
Proven reliability in mission-critical systems
Keywords: 

Type B RCCB 100A
EV charger protection
industrial leakage breaker
1000Hz RCD
DIN rail circuit breaker
Trusted Solution: ZHISHUN Electric's ZSL1-1B delivers unmatched electrical safety for high-power systems, protecting both equipment and personnel through advanced leakage current detection technology.
Parâmetros técnicos
CategoryParameterSpecification
Standard CertificationCompliance StandardsIEC 61008-1, IEC 62423
Tipo de ProteçãoGround Fault ProtectionElectromagnetic Trip
Residual Current TypeType BDetects: AC, pulsating/smooth DC (≤1kHz)
Configuration OptionsPole Configurations2P(1P+N), 4P(3P+N) – N Pole on left
Current Ratings2P(1P+N)16,25,32,40,63A (80,100A as 3 modules)
4P(3P+N)16,25,32,40,63,80,100A
Voltage Ratings2P(1P+N)110/230/240V
4P(3P+N)240/400/415V
InsulationInsulation Voltage (Ui)500V
FrequencyRated Frequency50/60Hz
SensitivityResidual Operation Current (IΔn)30,100,300mA
Breaking CapacityResidual Making/Breaking (IΔm)500A (In≤50A), 10In (In>50A)
Short-Circuit Current (Inc=IΔc)10,000A
SCPD Fuse Rating10,000A
Response TimeResidual Current Off-Time≤0.1s
Voltage WithstandImpulse Withstand (1.5/50μs)4kV
Dielectric Test (1min)2.5kV
DurabilityElectrical Life2,000 cycles
Mechanical Life4,000 cycles
IndicatorsContact PositionGreen=OFF, Red=ON
Ground FaultWhite=Normal, Red=Leakage
ProtectionProtection DegreeIP20
EnvironmentOperating Temperature-25°C to +40°C
HumidityMax 95%
TerminalsConnection TypeCable/Pin-type/Fork-type busbar
Tamanho máximo do cabo35mm²
Tightening Torque2.5N·m
InstallationMontagem35mm DIN Rail
Direção da fiaçãoBi-directional

Dimensions

1. Comprehensive Leakage Protection for Modern Systems

Type B Detection Technology

  • Detects AC, pulsating DC, and smooth DC leakage currents
  • Complies with IEC 61008-1 & IEC 62423 for superior safety

Wide Frequency Range (0-1000Hz)

  • Ideal for inverters, VFDs, and EV chargers

2. High-Current Capacity & Industrial Reliability

🔹 100A rated current for heavy-duty commercial/industrial use
🔹 -25°C to +40°C operating range withstands harsh conditions
🔹 Bidirectional wiring for flexible installation

3. Precision Protection & Safety

⚡ Adjustable sensitivity: 30mA/100mA/300mA
⚡ Accurate tripping: ≥0.4IΔn or 10mA (whichever is higher)
IP20 protection for long-term durability

4. Globally Certified & Compliant

🌍 CE, CB, TUV, UKCA certified
🌍 Meets international standards for EU, UK, and global markets


Ideal Applications

🏭 Industrial automation – Motors, VFDs, production lines
🔌 Estações de carregamento de VE – DC leakage protection
☀️ Solar/storage systems – Inverter compatibility
🏥 Medical equipment – Ensures patient safety
💻 Centros de dados – Prevents critical power failures


Key Advantages

True Type B protection – Beyond standard AC RCDs
100A high-load capacity – Industrial & commercial use
Wide frequency detection – Supports modern power electronics
Global compliance – Export-ready certification
Easy installation – Bidirectional wiring saves time

Keywords:
RCCB Tipo B, 100A residual current device, EV charging protection, IEC 61008 certified, industrial leakage breaker

P1: Gostaria de saber se aceitam pequenas encomendas?

R1: Não se preocupe. Sinta-se à vontade para nos contactar para obter mais encomendas e dar mais conveniência aos nossos clientes ,Aceitamos pequenas encomendas.

P2: Podem enviar produtos para o meu país?

R2: Claro, Podemos. Se não tiver o seu próprio transitário, Podemos ajudá-lo.

P3: Podem fazer OEM para mim?

R3: Aceitamos todas as encomendas OEM,Basta contactar-nos e enviar-nos o seu design. Nós ofereceremos um preço razoável e faremos amostras para si o mais rápido possível.

P4: Quais são os vossos termos de pagamento ?

R4: Por T/T,LC à vista,30% Depósito antecipado, Saldo 70% Contra cópia do B/L.

P5: Como posso fazer a encomenda?

R5: Primeiro assine o PI,Pague o depósito,then we will arrange the production.After the goods finished production we will send u the copy of B/L then u paid. Finally u will get the goods.

Q7: When can I get the quotation ?

A7: We usually quote you within 24 hours after we get your inquiry. If you are very urgent to get the quotation.Please call us or tell us in your mail, so that we could regard your inquiry priority.

Escolha de envio

Seguinte:

Deixar uma resposta

Deixe uma mensagem